Managing data calls 
409
Administered Connection 
15
through tie trunks (ISDN, DS1, or analog tie trunks) and intermediate switches. If 
required, route the connection via Automatic Route Selection (ARS) and 
Generalized Route Selection (GRS) through the public network. The call routes 
over associated ISDN trunks. When the far-end answers, a connection occurs 
between the far-end and the near-end extension in the 
Originator
 field on the 
AC screen.
Because the system makes an administered connection automatically, you do not 
use the following:
Data Call Setup
Do not assign a default dialing destination to a data module when it is used 
in an AC.
Data Hotline
Do not assign a hotline destination to a data module that is used in an AC.
Terminal Dialing
Turn off terminal dialing for data modules involved in an AC. This prevents 
display of call-processing messages (INCOMING CALL,...) on the 
terminal.
Access endpoints
Access endpoints are non-signaling trunk ports. They neither generate signaling to 
the far-end of the trunk nor respond to signaling from the far-end. Designate an 
access endpoint as the originating endpoint or destination endpoint in an AC. 
Typical AC applications
The following are typical AC applications:
A local data endpoint connection to a local or remote-access endpoint. 
Examples: an MPDM ACCUNET digital service connecting to SDDN via 
an ISDN trunk-group DS1 port; an MPDM ACCUNET digital service 
connecting to an ACCUNET Switched 56 Service via a DS1 port.
A local-access endpoint connecting to a local or remote-access endpoint. 
Examples: a DSO cross-connect and a 4-wire leased-line modem to a 
4-wire modem connection via an analog tie trunk.