Introduction to the DEFINITY system 
22
Controlling the calls your users can make and receive 
2
Changing feature access codes
Feature access codes (FAC) allow users to activate and deactivate features from 
their phones. A user who knows the FAC for a feature does not need a 
programmed button to use the feature. For example, if you tell your users that the 
FAC for the Last Number Dialed is *33, then users can redial a phone number by 
entering the FAC, rather than requiring a Last Number Dialed button.
Many features already have factory-set feature access codes. You can use these 
default codes or you can change them to codes that make more sense to you. 
However, every FAC must conform to your dial plan and must be unique. For 
more information about the dial plan, refer to 
‘‘Understanding the dial plan’’ on 
page 19
.
Let’s try an example. If you want to change the feature access code for Call Park 
to *72:
1. Type 
change feature-access-codes
 and press 
RETURN
.
The 
Feature Access Code
 screen appears.
2. Move the cursor to the Call Park Access Code field.
3. Type 
*
72
 in the access code field over the old code.
4. Press 
ENTER
 to save your changes.
If you try to enter a code that is assigned to a feature, the system warns you 
of the duplicate code and does not allow you to proceed until you change 
one of them.
Tip:
To remove any feature access code, merely delete the existing FAC and leave 
the field blank.
Controlling the calls your users can 
make and receive
The DEFINITY ECS provides several ways for you to restrict the types of calls 
your users can make, and the features that they can access. 
You use Class of Restriction (COR) to define the types of calls your users can 
place and receive. Your system may have only a single COR, a COR with no 
restrictions, or as many CORs as necessary to effect the desired restrictions. 
You will see the COR field in many different places throughout the DEFINITY 
system - when administering phones, trunks, agent logins, and data modules, to 
name a few. You must enter a COR on these screens, although you control the 
level of restriction the COR provides.