Screen reference
486
Attendant Console
17
Port
Enter seven characters.
Each attendant console requires a port on a digital line circuit pack. For reliability,
the attendant consoles should not be assigned to ports on the same digital line
circuit pack. For example, if three attendant consoles are to be provided, assign
each console to a port on three different digital line circuit pack, if possible.
However, if required, all attendant consoles can be assigned to ports on the same
digital line circuit pack.
the attendant consoles should not be assigned to ports on the same digital line
circuit pack. For example, if three attendant consoles are to be provided, assign
each console to a port on three different digital line circuit pack, if possible.
However, if required, all attendant consoles can be assigned to ports on the same
digital line circuit pack.
Name
Enter the name of this console.
Group
Valid entries
Usage
01
through
44
First and second characters are the cabinet number.
01
through
03
01
A
through
E
Third character is the carrier.
01
through
20
Fourth and fifth characters are the slot number.
01
through
08
(digital line
circuit pack)
Sixth and seventh characters are the circuit number
01
through
16
(2-wire
digital circuit pack)
01
through
24
(2-wire
digital circuit pack TN2224)
x
Indicates that there is no hardware associated with
the port assignment. An individual attendant
extension must be assigned in the Extension field.
the port assignment. An individual attendant
extension must be assigned in the Extension field.
Valid entries
Usage
Up to 27 alphanumeric characters.
Any entry is accepted
Valid entries
Usage
1
to
16
Enter the Attendant Group number