Lucent Technologies Medical Alarms Release 3 Version 8 User Manual

Page of 114
 
 
Upgrading CMS to the High Availability Option 
CentreVu CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Setting Up the Alarm Originator
3-59
8. Enter
 y
. The system automatically reboots and the remote console 
port comes up as a regular dial-in port with the 
login:
 prompt 
displayed.
As the system reboots, the shutting-down messages appears on the 
remote console. When the system starts to come back up, the 
system boot diagnostics should appear on the local console. After 
the system reboots, a login prompt should appear on the local 
console.
9. Log into the local console as 
root.
The console has been redirected from the remote console to the 
local console.
Setting Up the Alarm Originator
3
For information on setting up the alarm origination manager on the HA 
servers, see “CentreVu CMS R3V8 Alarm Origination Manager (585-215-
884). 
Setting Up the NTS
C
For information about setting up the NTS, see “Setting up the NTS”, in 
Chapter 2 of “CentreVu Call Management System R3V8 Software 
Installation and Setup” (585-210-941). 
Configuring the 
NTS 
3
This procedure is performed on NTS devices when:
the NTS is newly installed, or 
the NTS requires reconfiguration during a manual HA server switch-
over after the HA server to which the NTS was initially connected 
has experienced a failure event  
1. Connect a dumb terminal to the Console Port on the rear of the NTS 
using the console cable and adapter that came with the NTS. On 
the 8- and 16-port NTSs, the Console Port is port #1.
You will need the following for the 8- and 16-port units:
Console Cable
Adapter - comcode 407361823
Null Modem - comcode 407122043.