LSI 53C810A User Manual

Page of 238
7-4
Electrical Characteristics
Table 7.6
Capacitance
Symbol
Parameter
Min
Max
Unit
Test Conditions
C
I
Input capacitance of input pads
7
pF
C
IO
Input capacitance of I/O pads
10
pF
Table 7.7
Output Signals—MAC/_TESTOUT, REQ/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
16 mA
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OH
Output high current
8
mA
V
DD
0.5 V
I
OL
Output low current
16
mA
0.4 V
I
OZ
3-state leakage
10
10
µ
A
Note: REQ/ has a 100
µ
A pull-up that is enabled when TESTIN is low.
Table 7.8
Output Signal—IRQ/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
8 mA
V
OL
Output low voltage
V
SS
0.4
V
8 mA
I
OH
Output high current
4
mA
V
DD
0.5 V
I
OL
Output low current
8
mA
0.4 V
I
OZ
3-state leakage
10
10
µ
A
Note: IRQ/ has a 100
µ
A pull-up that is enabled when TESTIN is low. IRQ/ can be enabled with a
register as an open drain with an internal 100
µ
A pull-up.