Logic 3 V5.00 User Manual

Page of 134
COM Port 
The DVR COM port to which the terminal is connected.  Ensure that the COM port 
settings match those of the terminal. 
Register Number 
The POS register number. 
POS Alarm Settings 
Enabled 
Enables a certain text trigger to fire an alarm event which will be recorded as POS 
alarm footage (if data partitions have been enabled), as well as fire an output relay if 
desired. 
Dwell Time 
The time in seconds that the POS alarm event will last for.  This pertains to the 
length of video footage that will be recorded. 
Output Relay 
Select the output relay to trigger when the text trigger is fired. 
Trigger 
There are two trigger types: a momentary trigger of 2 seconds or a latched trigger 
which will stay triggered until it is manually disabled via the Live Viewer Relays 
button. 
Filter Settings 
The Filter Settings screen is where you customize which POS data items will cause a 
POS data alert. 
 
 
 
No Sale/Void 
Enables POS data alerts for all No Sale and/or Void items. 
Price Triggers for 
Items 
You can set a POS data alert that will occur when any item is greater/equal/lesser 
than the value you set. 
Items/Codes 
Set a POS data alert for particular items and/or codes. 
3xLogic Vigil System Server Software - User’s Guide    Doc# 08100610 Page 
104