7. LED Indication List 
Check Point
Action
LED
Indication
Symptom
Failure 
PCB
Reference
Status LED
Solid Green  Lamp Hour Over 
1400 Hr.
See details in 
User's Manual
1. Change New 
Lamp             
2. 
Reset the Lamp 
Hour
Status LED
Flash Green  1. Fan Spin
DMD 
Board
Plug Power core 
to see fan spin or 
not
1. Change the Fan
2. Door Lock
Main 
Board
Force to contact 
the doorlock to see 
it works ok or not
1. Change the 
Doorlock switch
3. Color wheel
DMD 
Board
To turn on the 
projector to hear 
the color wheel is 
running or not
1. Follow the Power 
can not be truned 
on Trouble 
shoutng guide
4. Lamp
Waiting the 
system already 
cool down, and 
the above 3 items 
is OK, but the 
Lamp is not 
striked on   
1. Change the Lamp 
2. 
If still not works, 
change the 
ballast
5. Thermal
Main 
Board
After few minutes 
operation, the 
system is 
automatically 
power down.
1. Thermal Problem
Power LED  Solid Orign
Standby Power
Power LED
Flash Green  Power on 
Sequence
Power LED  Solid Green  Normal Operation
Power LED  Flash Orgin Power off 
Sequence