PLANNING YOUR INSTALLATION 
 
PAGE 5 
FLOOR PROTECTION  - Optima 2 FS 
 
This appliance requires noncombustible floor protec-
tion. If the floor protection is to be stone, tile, brick, etc., 
it must be mortared or grouted to form a continuous 
non-combustible surface. If a chimney connector ex-
tends horizontally over the floor, the protection must 
cover the floor under the connector and at least 2" to 
either side.  
 
A noncombustible floor protector must fully cover the 
area beneath the appliance and extend 6” to the front, 
6” to the sides, and up to 6" from the back as illus-
trated on this page. 
 
 
*Note: When installed at clearances less than 6”, floor pro-
tection is only required to extend to the wall. 
 
Top View of Model: Optima 2 FS 
 
 
 
 
 
Up to * 6"/153mm 
minimum
 
6"/ 
153mm 
min.. 
6"/ 
 153mm 
min.
 
Rear 
Front 
  6"/ 
153mm 
min.