Lenovo S2110A User Manual

Page of 46
Lenovo IdeaTab S2110A Hardware Maintenance Manual
22
Perform operational charging. If the battery status indicator or icon does not 
light on, remove the battery pack and let it return to room temperature. Reinstall 
the battery pack. If the charge indicator or icon is still off, replace the battery 
pack.
If the charge indicator still does not light on, replace the system board. Then 
reinstall the battery pack. If it is still not charged, go to the next section.
Checking the battery pack
Battery charging does not start until the Power Meter shows that less than 95% 
of the total power remains; under this condition the battery pack can charge to 
100% of its capacity. This protects the battery pack from being overcharged or 
from having a shortened life.
To check your battery, move your cursor to the Power Meter icon in the icon tray 
of the Windows
®
 taskbar and wait for a moment (but do not click it), and the 
percentage of battery power remaining is displayed. To get detailed information 
about the battery, double-click the Power Meter icon.
Note:
 If the battery pack becomes hot, it may not be able to be charged. Remove 
it from the computer and leave it at room temperature for a while. After it cools 
down, reinstall and recharge it.
To check the battery pack, follow the steps below:
1. Turn off the computer.
2. Remove the battery pack and measure the voltage between battery terminals 
1 (+) and 7 (-). See the following figure:
3. If the voltage is less than +11.0 V DC, the battery pack has been discharged.
Note:
 Recharging will be continued for at least 3 hours, even though the 
indicator does not light on.
If the voltage is still less than +11.0 V DC after recharging, replace the battery.
4. If the voltage is more than +11.0 V DC, measure the resistance between 
battery terminals 5 and 7. The resistance must be 4 to 30 KΩ.
If the resistance is not correct, replace the battery pack. If the resistance is 
correct, replace the system board.
1(+)
2(+)
3 4
5
6(-)
7(-)
Terminal
1
+0 to +14
7
Ground (-)
Voltage (V DC)