Lantronix Network Hardware 900-598 User Manual

Page of 109
   
PremierWave XC User Guide 
 
91
 
13:  Events 
Event Overview 
The PremierWave XC supports configuration of several alerts for specific events detected. The 
supported alerts are SMS text messaging, SNMP traps and PremierWave’s built in Relay Output 
control.  Different events such as Input 1, Input 2, Main Power Fail, Backup Power Fail, Wwan0 
Link Down and Ethernet Link Down could be configured to generate alerts. 
Main and Backup Power Failure - PremierWave monitors both input power states and triggers 
one or more configurable alerts. 
Cellular and Ethernet Interface Down Event - PremierWave monitors the Primary Interface 
configurable remote host reachability (Primary Interface DNS Servers if not configured) state and 
triggers one or more configurable alerts when the remote host becomes unreachable. 
I/O Inputs 1 and 2 Signal Status Change - PremierWave monitors I/O input state changes 
(configurable high2low or low2high) and triggers one or more configurable alerts. 
When an event is enabled and detected, the status of the event will be displayed in both CLI and 
Web Manager. An event is cleared when the event has been rectified or cleared by the Clear 
Event command via Web or CLI. PremierWave event states are also cleared during system 
initialization. 
Event Alerts 
The following alerts can be configured to be triggered when an event occurs. 
Table 13-1 Event Alerts Settings 
Event Alert Settings
 
Description 
Input Event 
Configure the input event to trigger on a low to high or high to low signal. 
Note: 
This setting is only available for Input 1 and 2 event.
 
Relay output 
Enable or disable the Relay output 
Note: 
Enable selected, will close the Relay output
 
Note: 
Disable selected, will not affect the Relay output.
 
Send SMS 
Enable or disable the Send SMS alert 
Input the recipient number (up to 5) and message body. 
Note:  
Wwan0
 link with GSM must be up.
 
Therefore, Send SMS alert is not available for 
Wwan0
 Link Down event. 
Send SNMP Trap 
Select Enabled or Disabled to enable or disable the SNMP Trap 
Note: 
 must be configured beforehand.