Lantronix Computer Hardware 900-581 User Manual

Page of 212
4: Configuration Using XML
PremierWave EN Command Reference
20
XML Configuration Groups
 lists the PremierWave EN XCR groups in alphabetical order. This table indicates the 
various group items, as well as some possible value names and options.
Note:
Any instance of &#60 in the table may be read as "less than" and any instance of 
&#62 may be read as "greater than".
Table 4-7  XCR Groups
Group Name
Group Item
Value Name
Value Options
Additional 
Information
alarm
barrel connector 
power
connect (Attribute of 
“instance” is a 
number.)
email
input <instance>
connect <instance>
email
terminal block power
connect reminder 
interval
connect <instance>
email
analog input 
(Attribute of 
“instance” is a 
number.)
adjustment
simple offset, scale 
and offset
Default: simple offset 
alarm high
Default: 0.0
alarm low
Default: 0.0
alarm type
none, high, low, high 
and low 
Default: none
decimal point
Default: 5
delay
Default: 0 seconds
display
enable, disable
Default: enable
input high
Default: +1.0
input low
Default: 0.0
offset
range
100mv, 1v, 10v, 
20ma 
Default: 10v 
reading high
Default: +1.0 
reading low
Default: 0.0
title
units
Default: V