LaCie FIREWIRE 800/400 User Manual

Page of 59
LaCie Biggest Quadra
User Manual
page 
Setting Up the Biggest Quadra
4.1. Setting the RAID Level
The LaCie Biggest Quadra is pre-configured at RAID 
level 5, but it may be re-configured. The RAID level is set 
using the RAID Level Switch Selectors on the rear panel of 
the LaCie Biggest Quadra. The RAID level selectors consist 
of two switches, with four possible switch position combina-
tions: RAID 0, 0 + 1, 5 and 5 + Hot Spare.
CAUTION:
 The  LaCie  Biggest  Quadra  must 
be powered off to change the RAID level.
ImpOrTANT  INfO:
  In  the  event  that  the 
RAID level does not correspond to both the disk 
settings and the RAID Level Switch Selectors, the 
LCD  will  display  the  following  two  alternating 
messages:
1. “RAID level” 
“Unmatched”
2. “Current: Rx” (i.e. the current RAID level set-
tings of the installed disks) 
“Original: Rx” (i.e. the RAID level settings on 
the RAID Level Switch Selectors)
Example:
The RAID Level Switch Selectors are posi-
tioned to indicate a RAID 0 setting, but the 
disks were set earlier as a RAID 5 array, the 
LCD will display the following two alternating 
messages:
1. “RAID Level” 
“Unmatched”
2. “Current: R5” 
“Original: R0”
In this situation, the array will not function. 
There are two options:
1. Shut down the LaCie Biggest Quadra and 
re-position the RAID Level Switch Selectors 
to the previous RAID setting, in this case, 
RAID 5.
2. Re-insert the four drives, and re-create the 
array as a RAID 0 array. If there is any data on 
the disks, it will be lost during the initializa-
tion.
CAUTION:
 If there is data on the array, chang-
ing the RAID level may lead to the loss of all of 
the data on the array.