LaCie FIREWIRE 800/400 User Manual

Page of 59
LaCie Biggest Quadra
User Manual
page 
Using the Biggest Quadra
5.2.3. Failure and Error Messages
These messages will be displayed in the event of a 
RAID or disk failure, or an error during a process.
RAID Failure Messages
LCD Display
Message
Message Cleared When...
RAID Fail
code: 0
The RAID array failed. There are not 
enough disks for the RAID array to 
operate.
A disk is re-installed
RAID Fail
code: 1 <---->
The RAID array failed. The sequence 
of the disks in the array is incorrect. 
The current sequence is displayed 
within the “<---->” space.
The original disk sequence is 
restored
RAID Fail
code: 2
The RAID array failed but all original 
disks are existing after restarting the 
unit.
The RAID array is recreated.
Disk Failure Message
LCD Display
Message
Message Cleared When...
DISK x Fail
Disk “x” failed.
The failed disk is replaced
Fan Failure Message
LCD Display
Message
Message Cleared When...
FAN Fail
xxxx rpm
Fan failure.  xxxx rpm = the current 
speed of the fan
The failed fan is repaired or replaced