Iwatsu ADIX VS Owner's Manual

Page of 172
ADIX-VS General Description - 11 
Key Telephone Lamp Indications 
Status   
 
 
 
Lamp Indication 
I-Use (Green) ....................................... Modulation Steady (On) 
CO Incoming/Call Forward.................. 0.1 sec. on, 0.9 sec. off 
I-Hold (Green) ..................................... 0.5 sec. on, 0.5 sec. modulated on 
System Hold/Non-Privacy .................... 0.1 sec. off, 0.3 sec. modulated on 
Recall, ICM Incoming, MSG ............... 0.7 sec. off, 0.3 sec. modulated on 
DND.................................................... 0.5 sec. on, 0.5 sec. modulated on 
Busy..................................................... Steady (On) 
Station Port Requirements 
Model 
Description 
Ports Required 
IX-12KTS-3....... 12 line keys (24 line keys with IX-12ELK-3) ........... 1 
IX-12KTD-3 ...... 12 line keys (24 line keys with IX-12ELK-3) ........... 1 
IX-12KTS-2....... 12 line keys (24 line keys with IX-12ELK) .............. 1 
IX-12KTD-2 ...... 12 line keys (24 line keys with IX-12ELK) .............. 1 
IX-VT................ Versa-Phone ............................................................ 1 
IX-MKT ............ Digital Key Telephone............................................. 1 
DCKT970  ......... Digital Wireless Telephone...................................... 1 
or shared with 
digital telephone 
IX-DCKT900..... Digital Wireless Telephone...................................... 1 
or shared with 
digital telephone 
IX-DDPH........... Digital Doorphone ................................................... 1 
IX-BPAD........... Busy Bypass Unit for IX-12KTx-2 ........................... 1 
Time Parameters 
Hold Recall Timer................................ 0 - 255 seconds 
Timed Trunk Queuing ......................... 1 - 20 minutes 
Doorphone Answer Time ..................... 5 - 255 seconds 
Hunting Time ...................................... 0 - 255 seconds 
Night Mode Start Time ........................ 00:00 - 23:59 
Auto CO Answer Start Time ................ 00:00 - 23:59 
MISC Relay Timer............................... 10 - 255 ms 
System Numbering Plan 
ADIX-VS has a Flexible numbering plan. Default numbering is three digits. 
Station length can be changed to two, three, or four digits in length.