IPSO IHC WASHER-EXTRACTORS IHC030 User Manual

Page of 24
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
10
5-08-52
Electrical Installation Requirements - Model IHC018
Only trained personnel should perform this 
procedure. Use caution while servicing 
machines with covers removed and power 
applied.
W700
WARNING
Boiler Fed/Steam Heat
Electric Heat
Code
Vo
lta
g
e
Cycle
Phase
Wi
re
Full Load
Amp
s
Recommended 
Circ
uit Brea
ker
(US-market)
AW
G
/m
m
2
kW S
tand
a
rd 
Hea
ting Elemen
ts
Full Load
Amp
s
Recommended 
Circ
uit Brea
ker
 
(US-market)
AW
G
/m
m
2
US NON-US
US
NON-US
N 440-480
50/60
3
3+PE
4
10
10
14/2.5
3x2 kW
N/A
N/A
N/A
N/A
P
380-415
50/60
3
3+N+PE
12
15
16
14/2.5
21
30
25
10/6.0
Q 200-240
50/60
3
3+PE
12
15
16
14/2.5
27
30
32
10/6.0
X 200-240
50/60
1/3
2/3+PE
12
15
16
14/2.5
N/A
N/A
N/A
N/A
Alternative Electric Heat Options
N 440-480
50/60
3
3+PE
3x1.4 kW
N/A
N/A
N/A
N/A
P
380-415
50/60
3
3+N+PE
18
20
20
12/4.0
Q 200-240
50/60
3
3+PE
23
30
25
10/6.0
X 200-240
50/60
1/3
2/3+PE
N/A
N/A
N/A
N/A
N 440-480
50/60
3
3+PE
3x3 kW
N/A
N/A
N/A
N/A
P
380-415
50/60
3
3+N+PE
25
30
32
10/6.0
Q 200-240
50/60
3
3+PE
35
40
40
8/10.0
X 200-240
50/60
1/3
2/3+PE
N/A
N/A
N/A
N/A
N 440-480
50/60
3
3+PE
3x4 kW
21
30
25
10/6.0
P
380-415
50/60
3
3+N+PE
29
40
32
8/10.0
Q 200-240
50/60
3
3+PE
N/A
N/A
N/A
N/A
X 200-240
50/60
1/3
2/3+PE
N/A
N/A
N/A
N/A
Table 2