Infocus PN-L702B User Manual

Page of 46
Page 25
INF7020 Hardware Guide
Function Menu
You can return the settings to their factory-preset values and restrict operations from the hidden Function menu.
To access the Function menu:
1) 
Hold the SIZE button down until “F” appears in the upper left corner of the screen.
2) 
While “F” appears, press up, right, down, and left arrow buttons in that order.
3) 
The Function menu appears.
 
▲▲▲▲
OFF
UNLOCKED
ON1
ON
LED
OFF
MONITOR
FUNCTION
1/1
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C
OSD DISPLAY
LED
TEMPERATUREALERT
STATUSALERT
POWER BUTTON
CONTROLLER INPUT
END…[MENU]
▲▲▲▲
ALL RESET: Resets the settings to the factory default settings. Press the right arrow button, select ALL RESET, and then press the 
MENU button. After initialization, turn the monitor power switch off and then back on.
ALL RESET1 - Resets all the settings to the factory default settings.
ALL RESET2 - Returns all settings to the factory default settings except for the following items: LAN SETUP, RS232C/LAN SELECT, 
BAUD RATE, NETWORK, MAIL, SERVICE & SUPPORT, and SNMP.
ADJUSTMENT LOCK: Defines which buttons on the remote control or monitor can be used.
OFF - Enables operation.
ON 1 - Disables all operations other than turning power on/off and FUNCTION.
ON 2 - Only the FUNCTION operation is enabled. Disables all operations other than FUNCTION (not even power on/off).
ADJUSTMENT LOCK TARGET: Defines whether the remote control or monitor can be used.
REMOTE CONTROL - Prohibits remote control operation.
MONITOR BUTTONS - Prohibits monitor button operation.
BOTH - Prohibits remote control and monitor button operation.
RS232C: Specifies whether to allow RS232C control.
OSD DISPLAY: Defines which menus, modes, and messages are displayed. Note: The FUNCTION screen cannot be hidden.
ON 1 - Shows all menus, modes, and messages.
ON 2 - Hides messages automatically displayed by the display. Shows messages during operation.
OFF - Hides all menus, modes, and messages.
LED: Specifies whether to light the power LED. OFF cannot be selected when STANDBY MODE is LOW POWER.
TEMPERATURE ALERT: Selects the notification method for an abnormal temperature.
OFF - Do not notify about an abnormal temperature. 
OSD & LED - When an abnormal temperature is detected, the power LED flashes red and green alternately and the screen 
displays a message: TEMPERATURE. 
LED - When an abnormal temperature is detected, the power LED flashes red and green alternately.
STATUS ALERT: Selects the notification method for a hardware error.
OFF - Do not notify about the error.
OSD & LED - When a hardware error is detected, the power LED flashes red and the screen displays a message: STATUS [xxxx].
LED - When a hardware error is detected, the power LED flashes red.