APC Fluid Cooler 57MBH@25 TD, 10GPM, 5Feeds, 400/3/50 ACFC75256 User Manual

Product codes
ACFC75256
Page of 56
1
InRow RD Technical Data Manual
Overview
The modular, row-based computer 
room cooling system offers efficient, 
predictable, and economical cooling 
for a variety of spaces.
Critical environmental requirements 
now reach far beyond the confines of 
the traditional data center or com-
puter room to encompass a larger 
suite of applications, referred to as 
technology rooms. Critical environ-
ment applications include:
•  Computer rooms
•  Telecommunication facilities
•  Clean rooms
•  Power equipment
•  Medical equipment rooms
•  LAN/WAN environments
A worldwide network of APC repre-
sentatives is fully qualified to 
provide engineering, sales, installa-
tion, and service for our products. 
APC warrants all parts for 12 months 
from the date of purchase. Extended 
warranties are available.
Capacities
InRow RD units are available in two 
sizes (300mm and 600mm) with 
nominal capacities ranging from 
2-10kW (300mm) and 10-29kW 
(600mm).
Room Air Distribution
Row-based systems are placed in line 
with rack enclosures. At least one 
system is used per hot aisle. Air is 
drawn in through the rear of the sys-
tem, cooled, and discharged into the 
cold aisle, thereby neutralizing the 
sensible heating effects of the data 
processing equipment.  The InRow 
RD delivers high volumes of airflow 
to eliminate hot spots in densely pop-
ulated environments.
Configuration
• Air-cooled
• Fluid-cooled
Compliance Approval
• UL Listed
• CE
• C-Tick
• C-UL Listed
Standard Features
All series:
• Variable-speed fans
• Shutdown input/alarm output
• 2-way/3-way floating point valve
• Top or bottom piping
• Network Management Card (NMC)
• Baying kit-InRow RD to 
NetShelter
®
 SX rack
• Remote temperature sensor
• Microprocessor controller
ACRD100 series and ACRD200 
series only:
• Insulated cabinet
• Washable filter
• Condensate management with two 
dual float condensate pumps 
• Scroll compressor
• Hot gas bypass
ACRD100 series only:
• Liquid line solenoid valve
ACRD500 series only:
• Backward inclined impeller
• Pleated 100-mm (4-in) filter
• NPT to BSPT pipe adapters
• Condensate management with one 
dual float condensate pump
• Variable speed reciprocating 
compressor using VFD control
• Pressure equalization solenoid
• Pipe adapters
Accessories
• Cable leak detector
• Baying kit-InRow RD to NetShelter 
VX rack
• NetShelter SX 42-U to 48-U height 
adapters
• NetShelter VX 42-U height adapters
• Bridge trough power cable shield
• Data cable bridge partition
• Isolation ball valves (ACRD100 
series only)
• Dry cooler
• Condenser