10
31
OTHER FUNCTIONS
Antenna rotation speed
The antenna rotation speed can be selected from 48
rpm and 36 rpm. (Default: 48 rpm)
Pushing and holding [–]/[
] for 1 sec. to select 36
rpm rotation speed, pushing and holding [+]/[
]
for 1 sec. to select 48 rpm rotation speed. 
Test pattern indication
To check the CRT indication distortion, a test pattern
can bee displayed.
While pushing and holding [MENU]/[
], turn power
ON to display the test pattern.
To return to normal operating condition, turn power
OFF then ON again.
Para-simulation screen
The MR-1000RII/TII has para-simulation screen capa-
bility.
q While pushing and holding [BRILL]/[
], turn
power ON.
w After the count down indication, stand-by screen ap-
pears.
e Push [TX (SAVE)]/[
] to display the para-
simulation screen.
r To return to normal operating condition, turn power
OFF then ON again.
All reset
q While pushing and holding [TARGET]/[
], [EBL1
(VRM1)]/[
] and [EBL2 (VRM2)]
/[
], turn power ON.
w Follow the guidance.