IBM Marine Radio DS4700 User Manual

Page of 270
CAUTION:
Disconnect the power cord before replacing the power supply and fan unit.
Complete the following steps to replace the power supply and fan units that you
removed before the installation:
1. Slide one power supply and fan unit into the storage subsystem. Be sure to
replace the power supply and fan units so that the lever on each power supply
and fan unit opens toward the interior of the storage subsystem, as shown in
Figure 28. Do not force fit. The power supply and fan unit is designed to prevent
it from being inserted into the chassis incorrectly.
Attention:
Be sure that the lever is pulled straight out as you slide the power
supply and fan unit into the storage subsystem, as shown in Figure 28. The left
and right power supply and fan units are seated in the DS4700 Express chassis
in opposite orientations. If you cannot fully insert the power supply and fan unit
into the power supply and fan unit bay, flip it 180° and reinsert it.
2. As you slide the power supply and fan unit into the empty slot, make sure the
guide pins on the side of the power supply and fan unit fit into the notches
along the sides of the power supply and fan unit bay. After the guide pins fit into
the notches and power supply and fan unit fits snugly into the slot, push the
lever upward or downward 90° depending on whether the power supply fan is
inserted in the left or right bay to fully latch it into place. Then gently push the
front of the power supply and fan unit to ensure that it is fully seated.
3. Repeat step and step to replace the second power supply and fan unit.
Replacing a dc power supply and fan unit
Statement 29:
Lever
Figure 28. Replacing a power supply and fan unit
50
IBM System Storage DS4700 Express Storage Subsystem: Installation, User’s and Maintenance Guide