IBM Partner Pavilion DS4100 User Manual

Page of 180
RAID
 
controller
 
Each
 
RAID
 
controller
 
contains
 
several
 
connectors
 
and
 
LEDs.
 
Each
 
controller
 
has
 
two
 
host
 
ports
 
and
 
one
 
expansion
 
port
 
for
 
connecting
 
the
 
storage
 
server
 
to
 
hosts
 
or
 
expansion
 
units.
 
You
 
first
 
insert
 
SFPs
 
into
 
the
 
ports
 
and
 
then
 
connect
 
the
 
fibre
 
channel
 
cables.
 
Host
 
ports
  
The
 
host
 
ports
 
(labelled
 
Host
 
1
 
and
 
Host
 
2)
 
are
 
used
 
to
 
connect
 
a
 
fibre
 
channel
 
cable
 
from
 
the
 
host
 
systems.
 
You
 
first
 
insert
 
an
 
SFP
 
into
 
the
 
port
 
and
 
then
 
connect
 
a
 
fibre
 
channel
 
cable.
 
The
 
two
 
host
 
ports
 
in
 
each
 
controller
 
are
 
independent.
 
They
 
are
 
not
 
connected
 
in
 
the
 
controller
 
module
 
as
 
they
 
would
 
be
 
in
 
a
 
hub
 
configuration.
 
The
 
host
 
port
 
connections
 
can
 
auto-negotiate
 
between
 
1
 
Gbps
 
and
 
2
 
Gbps.
 
Ethernet
 
port
 
The
 
Ethernet
 
port
 
is
 
used
 
for
 
an
 
RJ-45
 
10BASE-T
 
or
 
100BASE-T
 
Ethernet
 
connection
 
to
 
each
 
controller.
 
Use
 
the
 
Ethernet
 
connection
 
to
 
directly
 
manage
 
the
 
DS4100.
 
Expansion
 
port
 
The
 
expansion
 
port
 
(labelled
 
Expansion)
 
is
 
used
 
to
 
connect
 
additional
 
expansion
 
units
 
to
 
the
 
RAID
 
controllers
 
on
 
the
 
DS4100
 
base
 
storage
 
server.
 
You
 
first
 
insert
 
an
 
SFP
 
into
 
the
 
port
 
and
 
then
 
connect
 
a
 
fibre
 
channel
 
cable.
 
Note:
  
In
 
the
 
DS4100
 
single-controller
 
storage
 
server,
 
the
 
expansion
 
port
 
on
 
the
 
RAID
 
controller
 
is
 
not
 
active.
Serial
 
port
 
The
 
serial
 
port
 
is
 
used
 
by
 
service
 
personnel
 
to
 
perform
 
diagnostic
 
operations
 
on
 
the
 
RAID
 
controllers.
 
Incorrect
 
use
 
of
 
the
 
serial
 
port
 
can
 
result
 
in
 
loss
 
of
 
data
 
access
 
and,
 
in
 
some
 
cases,
 
in
 
loss
 
of
 
data.
Note:
  
The
 
maximum
 
baud
 
rate
 
is
 
57
 
600
 
bps.
Server
 
ID
 
switch
 
(enclosure
 
ID
 
switch)
 
The
 
server
 
ID
 
(also
 
referred
 
to
 
as
 
enclosure
 
ID)
 
switch
 
settings
 
range
 
from
 
0
 
through
 
7.
 
When
 
connecting
 
the
 
DS4100
 
base
 
storage
 
server
 
to
 
DS4000
 
EXP100
 
storage
 
expansion
 
units,
 
only
 
the
 
unique
 
IDs
 
ranging
 
from
 
00
 
through
 
07
 
can
 
be
 
set.
 
Host port 1
Host port 2
Ethernet
Expansion port (inactive in the DS4100
single-controller storage server)
AC power
connector
AC power
switch
Serial port
Server ID
switch
1 Gbps/
2 Gbps
switch
f10ug022scu
  
Figure
 
7.
 
Interface
 
ports
 
and
 
switches
 
for
 
DS4100
 
single-controller
 
storage
 
server
 
 
12
 
IBM
 
TotalStorage
 
DS4100
 
Storage
 
Server:
 
Installation,
 
User’s,
 
and
 
Maintenance
 
Guide