I-Data POLARIS Panel PC 19.1 inch User Manual

Page of 46
User manual 
POLARIS 
Panel PC 19.1'' and Panel PC 15'' 
Version 2.00 
 
Page 28 of 46
 
 
 
 
E_BMS790_POLARIS_PanelPC_19+15_Rev1.doc  
  User manual for POLARIS Panel PC 19.1" and 15"   
   Revision 1 / Status: January, 3
rd
, 2006   
   Technical data subject to change 
 
6.2 
RS 485 interface 
 
BARTEC supplies all the RS 485 interfaces as RS 422. 
Connection of a controller via an RS 485 interface of the POLARIS Panel PC. 
RS485 Modul 
Terminal compartment of the POLARIS Panel PC
 
Controller
 
PE
TxD A (TxD-)
RxD B (RxD+)
TxD B (TxD+)
TxD B (TxD+) / RxD B (RxD+)
TxD A (TxD-) / RxD A (RxD-)
RxD A (RxD-)
Data In
Data Out
Tx enable
17
18
 
See the interface description from the controller manufacturer for the relevant pin assignment of the controller. 
 
If it is intended to use the RS422 as an RS485 interface, Pin 21/Pin 23 and Pin 22/Pin 
 
must be bridged externally.  
 
 
Pin 19-23, 20-24, 21-25, 22-26  are already connected inside. 
In most cases, internal EMC measures allow the installation of termination resistors at 
the beginning and the end of the bus line to be dispensed with. 
Depending on local conditions, there might occasionally be impairments of data transfer. 
to other POLARIS Panel PCs or 
POLARIS Control 
if final device