74
Depth Offset 
(Advanced)
Settings:  -10.0  to  +10.0  ft,  or  -3  to  3  m  [International
Models only]; Default = 0
Depth Offset will adjust the digital depth readout to indicate depth from the
waterline  or  boat's  keel.  Enter  a  positive  vertical  measurement  from  the
transducer  to  the  waterline  to  read  the  depth  from  the  waterline.  Enter  a
negative vertical measurement from the transducer to keel to read the depth
from the keel. 
Temp. Offset 
(Advanced, with optional Temp/Speed only)
Settings: -10.0 to +10.0 degrees, Default = 0
Temp. Offset will adjust the temperature readout by the amount entered. This
menu  option  is  available  if  a  Temp/Speed  Accessory  is  connected  and  the
paddlewheel has moved at least once. 
Speed Calibration 
(Advanced, with optional Temp/Speed only) 
Settings: -20% to +20%, Default = 0%
Speed Calibration will adjust the speed readout by the amount entered. This
menu  option  is  available  if  a  Temp/Speed  Accessory  is  connected  and  the
paddlewheel has moved at least once.  
Local Time Zone 
(Advanced, with optional GPS only) 
Settings: Various,  Default  =  EST  [UTC-5]  -  Eastern
Standard Time
Local Time Zone selects your time zone in reference to the time reported by the
GPS receiver when Time+Date is selected as a Digital Readout on the Sonar
View (see Setup Menu Tab: Select Readouts). 