Huntington Grills ANSI Z21.58A-2008/CSA 1.6A-2008 User Manual

Page of 24
LEAK TESTING 
VENTURI TUBES 
All factory-made connections have been thoroughly tested 
for gas leaks.  However, shipping and handling may have 
loosened a gas fitting. 
AS A SAFETY PRECAUTION:  
 
TEST ALL FITTINGS FOR LEAKS BEFORE USING 
YOUR GAS BARBECUE. 
 
TEST THE CYLINDER VALVE FOR LEAKS EACH 
TIME THE CYLINDER IS FILLED. 
 
TEST FOR LEAKS EVERY TIME YOU CONNECT A 
GAS FITTING. 
 
DO NOT SMOKE! 
 
NEVER TEST FOR LEAKS WITH A LIGHTED 
MATCH OR OPEN FLAME. 
 
TEST FOR LEAKS OUTDOORS. 
TO TEST FOR LEAKS: 
1.  Extinguish any open 
flame or cigarettes in the 
area. 
2.  Be sure that cylinder 
valve and appliance 
valves are "off". 
3.  Connect LP gas 
cylinder.  See "Hose and 
Regulator". 
4.  Prepare a soap solution 
of one part water, one 
part liquid detergent. 
5.  With a full gas cylinder, open cylinder slowly. 
6.  Brush the soap solution on each connection. 
If your barbecue is equipped with a side burner or rear 
burner: 
a.  Place finger tip over the opening in the orifice at the 
end of hose. 
b.  Turn "SIDE"/"REAR" control to "HI". 
c.  Brush soap solution on each connection between 
orifice and control valve. 
d.  Turn "SIDE"/"REAR" control to "OFF". 
                      
 
 
 
 
 
 
 
 
 
 
   
         
 
7.  A leak is identified by a flow of bubbles from the area 
of the leak. 
8.  If a leak is detected, close the gas cylinder "shut-off" 
valve, tighten the connection and retest (Step 5). 
9.  If the leak persists, contact your barbecue dealer for 
assistance.  Do not attempt to operate appliance if a 
leak is present. 
 
KEEP VENTURI TUBES CLEAN. 
 
Blockages caused by spiders insects and nests 
can cause a flashback fire. 
Although the barbecue might still light, the backed up gas 
might also ignite and cause a fire around the venturi tubes 
at the control panel or side burner. 
 
        VENTURI TUBE 
        SPIDER WEB
 
 
If a flashback fire occurs, turn off gas at the 
source immediately 
Inspect and clean the venturi tubes (main burner, side 
burner, rear burner) if any of the following symptoms 
occur: 
1.  You smell gas. 
2.  Your barbecue does not reach temperature. 
3.  Your barbecue heats unevenly. 
4.  The burners make popping noises. 
Inspecting & Cleaning Venturi Tubes 
1.  Turn off gas at the source.  i.e. the gas cylinder or 
supply line for natural gas. 
2.  When barbecue is cool, remove burner fasteners from 
bottom, lift the burner from the barbecue housing. 
3.  Clean the venturi tubes with a pipe cleaner or venturi 
cleaning tool (Accessory #18270). 
4.  Lower the burner into position in the barbecue 
housing, making sure that the venturi tubes are 
correctly aligned and fitted on the orifices. 
5.  Secure burner with burner fasteners.