HP 288048 User Manual

Page of 30
Daily Gun Care
311053C
13
General System Maintenance
Clean the fluid and air line filters daily.
Check for any fluid leakage from the gun and fluid 
hoses. Tighten fittings or replace equipment as 
needed.
Flush the gun before changing colors and whenever 
you are done operating the gun.
Daily Cleaning Procedure
1.
2.
Clean the outside of the gun with a soft cloth damp-
ened with compatible solvent.
3.
To avoid damaging the spray tip, clean it with a com-
patible solvent and soft brush.
4.
If using an in-line filter, remove and clean it thor-
oughly in a compatible solvent.
5.
Clean the system's fluid filter and air line filter.
Daily Flushing Procedure
1.
2.
Remove the spray tip. Clean the parts.
3.
Supply a compatible solvent to the gun fluid inlet.
4.
Start the pump and operate it at its lowest pressure.
5.
Trigger the gun into a grounded metal waste con-
tainer until all the material is removed from the gun 
passages.
6.
7.
Disconnect the solvent supply.
CAUTION
This gun is not adjustable. To ensure proper shutoff, 
screw the piston cap (18) onto the housing (1) until it 
bottoms out.
Clean the front of the tip frequently during the day 
to help reduce buildup.
To reduce the risk of serious injury, including splash-
ing fluid in the eyes or on the skin, or static electric 
discharge when flushing:
Ensure that the entire system, including flushing 
pails, are properly grounded.
Remove the spray tip.
Maintain metal to metal contact between the gun 
and the flushing pail.
Use the lowest possible pressure.
Flush the pump and gun before the fluid can dry in 
it.
If it is available, the flushing procedure provided in 
the pump or sprayer manual should be used 
instead of this procedure.
F
IG
. 11
TI8174a