HP STORAGEWORKS SSL1016 User Manual

Page of 160
Installation and Configuration
40
Verification
When you first power on the autoloader, it automatically runs a Power On Self 
Test (POST). During the POST, the right (amber) LED flashes rapidly. After the 
POST, the left (green) LED illuminates steadily, and after approximately three 
minutes the LCD displays the HP logo and drive type. Do one of the following:
If the autoloader powers on successfully, continue configuring the autoloader. 
See “Configuration.”
If the autoloader does not power on successfully, make sure that:
— The rear power switch is on.
— The power cord is inserted correctly.
— The SCSI bus is terminated.
— The SCSI cable is connected to the autoloader and host computer.
— The On/Off button on the front of the autoloader has been pressed.
— There is not an error code displayed on the autoloader’s LCD. (If an error 
message is displayed, see Chapter 6, “Troubleshooting.”)
If you cannot resolve the problem yourself, contact your authorized service 
representative.
Configuration
To configure your autoloader, use the Configuration submenu on the front panel. 
When you first power on the autoloader, it defaults to no password protection. 
After you set the security option, however, all the configuration functionality is 
password-protected; you need an administrator-level password to configure the 
autoloader.