Honeywell Galaxy 3-48C Installation Instruction

Page of 90
Galaxy 3 Series Installation Manual
4-4
 Adding/Removing Keypads
Volume Control
Where fitted, the Mk7 keypad/keyprox has a volume control switch marked VOL at the bottom right-hand
corner of the pcb. Make sure the keypad/keyprox is powered up and adjust to the desired volume (+ or -)
for buzzer functions. Refer to Appendix F for keypad/keyprox part numbers with volume control function.
Adding a Keypad/KeyProx to the System
When adding a keypad to an existing system, the following points must be considered:
1.
Ensure that the keypad to be added has a unique address from the other keypads on the system.
2.
Ensure that the keypad has a valid address.
3.
Connect the keypad to the system - refer to the Keypad Installation Procedure.
Note:
A new keypad can only be configured into an existing Galaxy system from engineer mode.
4.
Access engineer mode.
5.
Connect the RS485 (AB) line of the keypad in parallel with the RS485 (AB) line of the
existing keypads.
6.
Connect + and – terminals of the keypad to a power supply.
7.
Exit engineer mode - engineer code + esc:
8.
The Mk7 keypad displays the message 1 MOD. ADDED — esc=CONTINUE.  Press the esc
key; the keypad returns to the unset banner.
NOTE: If this message is not displayed, the keypad is not communicating with the control panel and has not
been configured into the system. In this case all connections and addresses should be rechecked.
NOTE: If adding a keyProx to the system, the message 2 MOD ADDED will be displayed to indicate that
both a keypad and MAX have been added to the system.
9.
The keypad is now configured into the system.
Removing a Keypad/KeyProx from the System
A keypad can only be removed from an existing Galaxy system from engineer mode
1.
Access engineer mode.
2.
Disconnect the keypad.
3.
Exit engineer mode. The message 1 MOD. MISSING — [<],[>] to View is displayed
4.
Press the A or B key.  The message KEYPAD XX —   =REMOVE MODULE is displayed.
5.
Press the   key to acknowledge and accept that the keypad has been removed.  The keypad
returns to the unset banner.
NOTE: If removing a keyProx from the system the message 2 MOD MISSING is displayed to indicate
both a keypad and MAX have been removed from the system. Each should be removed separately
by pressing the * key twice.