A-7
Max Log
The Galaxy system has a 1000 event log (500 for 3-48) for the recording the MAX activations. This log is
shared by all readers on the system and operates on a first-in-first-out basis for overwriting events when the
log is filled.
To display the events in the MAX log select option 25 = ACCESS DOORS; use the A or B keys to select
the required MAX address then press the ent key. The first event that occurred on the selected MAX is
displayed along with details of the time, date and MAX number.
To view the log press the A key to move forward in time through the events or the B key to move
backwards. Press the esc key to return to the MAX address display. To view the log of another MAX,
use the A or B key to select the required address. To escape from the Access Doors option press the
esc key.
Max Events Print-Out
The MAX events can be printed out as they occur to an on-line printer. To print the MAX events
ensure that option 51.27 = PARAMETERS.On-Line Print is enabled. Select option 51.28 =
PARAMETERS.On-Line Level
 and enter 2 to print out all system events including the MAX events
or 3 to print out only the MAX events.
NOTE: A serial printer must be connected to line one of the Galaxy panel and the printer must remain
on-line (ready to print) at all times.