High End Systems DL.2 User Manual

Page of 322
CHAPTER 17 
Maintenance and Troubleshooting
214
DL.2 Digital Light User Manual
9. If the HEPA filter is discolored with particulates, replace it with the part listed in Related 
Reassemble the Fixture
Place HEPA 
filter with gasket 
against plenum
10. Reinstall the HEPA Filter with the rubber gasket 
down.
11. Reattach the filter bracket with the two philips pan 
screws.
12. Replace the prefilter over the bracket on velcro 
tabs.
13. Replace the top cover, fastening it with the two 
quarter-turn screws.
14. Carefully replace the rear bezel, making sure to  
position (but do not force) the gasket against the  
lamp cover located on the back of the projector.  
and Relatch the rear bezel assembly.
Gasket
Cleaning the Internal Projector Filter
Internal projector air filters prevent dust from 
accumulating on surface of Projection Lens and 
Projection Mirror. If the projector Air Filter becomes 
clogged with dust particles, it will reduce the cooling 
fans' effectiveness and may result in an internal heat 
build up that can shorten projector life. 
Projector
Filters
Filter 
Removal
Tool
Clean the projector air filter using the following steps: 
1. Disconnect the fixture from power. 
2. Rotate and lock the fixture head in the or 90° tilt 
position.
3. Unlatch and remove the rear bezel.
4. Loosen two quarter-turn screws to remove the 
bottom cover and locate the filter removal tool 
mounted on the chassis.
5. Loosen the 2 phillips head screws to remove the tool and use it
Loosen screws to 
remove tool
 to 
grasp and lift the two air filters from the internal projector.
6. Clean air filter with compresses air, a brush or wash out dust and 
particles with mild soap and water.
7. If the filter damaged, replace it only with the part listed in Related 
8. Replace completely dry filters in slot. The filters are keyed for positioning. Make sure that 
both filters are fully inserted.