Hitachi US7070447-001 User Manual

Page of 98
HiSpeed Switch Troubleshooting Guide
11-8
US7070447-001, Rev 01
Draft Level—Hitachi Confidential
Troubleshooting CIP
 Problem:
I’ve created a CIP service but still cannot connect to the ATM 
network.
 Solution:
Use the following solutions:

Verify that the CIP service has been created, admin status is enabled, 
and protocol state is ‘active’.
/ATM/SHOW/cip  <cip id>
/ATM/CONFIG/ENABLE/cip <cip id>

If using SVC connections, ensure that the ATM port is configured for 
SVC mode and ILMI is enabled.  By default, the ATM port is set to 
‘PVC’ mode and ILMI is disabled.
/ATM/CONFIG/MODIFY> port

If using SVC connections, ensure that you are using the same UNI 
signaling version as that of the connected ATM switch.
/ATM/CONFIG/MODIFY >port

If using SVC connections, ensure that you are using the same UNI 
signaling version as that of the connected ATM switch.
/ATM/CONFIG/MODIFY >port

If using SVC, verify that the ATM address of the ARP Server is 
correct.  Also, verify the ARP Server is up and active on the switch 
you are connecting to.
 Verify the following using 
/ATM/SHOW/connection:
OAM is up.
SSCOP, and ILMI is up. (for SVC only)
A CIP SVC or PVC connection is created per CIP instance.
ATM port connection and signaling. Operational status, Line 
state, Signaling status, and ILMI should be ‘up’. (for SVC only)
   
/ATM/CONFIG/MODIFY> port
 Verify the connection up time is increasing and status is ‘active’ 
for a specific VCC using  
VAC <VCC number>