BladeSymphony 1000 Architecture
 
White Paper
35
A SCSI or RAID type PCI card must be installed in a PCI slot in an I/O module to act as the controller of 
the storage module. A PCI card is combined with a storage module, as shown in Figure 25, by 
connecting the SCSI cable from the PCI card to the SCSI connector on the same I/O module, and then 
connecting the board wiring from the SCSI connector to server slot #4 to #7, where the storage module 
is installed through the backplane. The logical numbers of the SCSI connectors on I/O module #0 and 
#1 are defined as #0 to #1 and #2 to #3, respectively.
Figure 25. Connection configuration for HDD Modules
Bridge
Bridge
Bridge
Bridge
SCSI Bus
(Internally connected)
Sample Configuration
SCSI
SCSI
SCSI
SCSI
6x HDD
SCSI i/f
SCSI
#2
SCSI
#3
Server chassis
6 x HDD has only one 
SCSI I/F port.  
Note that this port is 
not connected.
Backplane
(Type 2)
I/O module #1 (type 2)
I/O module #0 (type 1)
SCSI connector # 3
SCSI connector #2
{
I/F #0
I/F #1
I/F #2
I/F #3
#15 #14
#13 #12
#11 #10
#9 #8
#7 #6
#5 #4
#3 #2
#1 #0
Bridge
Bridge
Bridge
Bridge
SCSI connector #0
SCSI connector #1
(1) 3x HDD Module
(2) 6x HDD Module
SCSI or RAID Card