9. Maintenance
AIR INLET NET
IMPORTANT
• Blowing air is taken in from the air inlet net. When air 
flow has dropped down during operation, stop the 
engine and inspect the air inlet net for blocking by 
obstacles.
• Note that failure to remove any such obstacles may 
result in the engine becoming overheated and dam-
aged.
                            (1) Net
WARNING
Never use the blower without the net of the blower. 
Before each use, check that the net is attached in 
place and is free from any damage. 
IGNITION COIL AIR GAP INSPECTION
• If the gap is out of standard or when installing the 
coil or rotor, adjust the air gap between the ignition 
coil and the iron core of the rotor.
Air Gap:
0.40mm (0.35 ~ 0.45mm)
0.016" (0.014 ~ 0.017")
        (1) Rotor
        (2) Ignition coil
10. Storage
BEFORE STORING THE BLOWER:
1. Drain a fuel tank and push the primer bulb until it 
becomes empty of fuel.
2. Remove the spark plug and drop a spoonful of 
2-cycle oil into the cylider. Crank the engine several 
times and install the spark plug.
3. Store unit in a dry, dust free place, out of the reach 
of children.