Hellenbrand Iron Curtain System User Manual

Page of 28
7
Instructions for Adding IC pH
Correction Media
See Figures 1, 2 & 3 on page 8..
1. Place Iron Curtain System on bypass. (Close inlet and
outlet valves and open bypass valve.)
2. Relieve pressure by manually advancing timer to back-
wash position (see page 10). Unplug control valve after
valve is shifted into backwash position and piston has
stopped moving. After pressure is relieved, proceed.
2A. If  your  type  “A”  Iron  Curtain  filter  is  equipped  with  an
optional “dome hole and bottom drain” proceed as fol-
lows otherwise advance to step three:
a. After pressure is relieved remove the dome
plug  by  turning  counter  clockwise.    Open  the
bottom drain
and allow approximately 15 inches
of water to drain out.
b.  Measure down through the dome hole to deter-
mine media level.  The media level may be as low
as 1/2 of the total tank height or as high as 2/3 of
the total tank height.
c. Add pH correction media and fill to a maximum
level of 2/3 of the total tank height.  Approximately
17-18 inches down from the top of the tank on an
IC-12 or IC-10 respectively.
d. Replace the dome hole plug being cautious not to
cross-thread.  Check the o’ring seal to be sure it
is clean from foreign debris.  Hand tighten only,
plus approximately 1/8 of a turn with a wrench.
Be careful not to overtighten causing damage to
the threads.
e. Proceed to step 11.
3. Remove  the  control  valve  from  tank  (see  page  14).
Determine if plumbing is rigid and able to support the
weight of the control valve assembly.
If the plumbing is rigid and able to support the weight of
the control valve assembly:
Remove the two adapter base screws and slide the tank
away from the control valve and plumbing so it is easier
to work on.
If  the  plumbing  is  unable  to  support  the  weight  of  the
control valve assembly:
IC-10A: Loosen the union nuts on the inlet and outlet and
disconnect plumbing. Loosen the fitting nuts on back of
air recharge and air bleed-off valves and remove tubing.
Loosen the fitting nut on drain line flow control housing
and remove tubing. Loosen the screw holding the drain
line flow control and disconnect the drain. Slide the tank
unit away from the plumbing so it is easier to work on.
IC-12A:  There  must  be  a  union  installed  on  the  inlet,
outlet, and drain line of control valve to proceed. If not,
they must be installed prior to proceeding.
 Loosen
the union on the inlet, outlet, and drain and disconnect
plumbing. Loosen the fitting nuts on back of air recharge
and air bleed-off valves and remove tubing. Slide the unit
away from the plumbing so it is easier to work on.
Remove the two adapter base screws and remove the
control valve assembly from the tank.
4. Remove the adapter base. Place the two adapter base
screws back in the adapter base and thread in until they
are  flush  with  the  bottom  of  the  adapter  base  but  not
touching the top of the tank. Carefully place a pry bar
5.
Plug in the electrical cord from the Iron Curtain Control
Center.  In  approximately  four  minutes,  the  aeration
pump will automatically turn on and begin to pump air
into  the  aeration  tank.  Allow  the  Iron  Curtain  Control
Center  to  finish  the  remaining  cycles  automatically
(approximately  25  minutes).  Make  certain  that  the
filter control is in the Service Position
 (piston all the
way out). Do NOT backwash filter at this time. Set time
of  day.  Time  of  regeneration  is  preset  for  12:00  a.m.
Regeneration frequency is preset for every three days.
(Type  A Filters are preset for every other day.) If you
wish to reset any of these factory settings, see page 9.
6.
Make  sure  the  filter  will  not  regenerate  within  24
hours  of  installation  to  allow  the  filter  media  to
absorb water and not be backwashed out.
7.
Open the outlet valve on the filter, then open the nearest
cold water faucet and allow the water to run until the air
stops  spurting  and  discoloration  is  gone.  Note:  It  is
normal for aerated water to appear effervescent.
8.
If the water softener was placed on bypass, close the
bypass valve and place the softener in service.
9.
Open the shut off valve to the water heater.
Regeneration Frequency
Your Iron Curtain Filter System contains a special filter media
mixture which allows it to filter iron longer than standard filters
between backwash regenerations. However, it is our recom-
mendation to leave factory settings as is, unless you wish to
backwash more frequently. You will have to backwash more
frequently if you have iron bacteria, hydrogen sulfide, and/or
manganese present in your water supply. You will also have
to regenerate more frequently if you notice iron bleed through
before the end of the normal service run.
Specifications
When supply water has a pH between 6.0 and 6.9, a Type A
filter  system  with  sacrificial  media  is  generally  used.  To
insure top performance this media needs to be replenished
periodically depending on water characteristics and usage
patterns,  generally  every  6  to  18  months.  This  can  be
determined by testing the pH of the water at a cold filtered tap
or  by  physically  measuring  the  amount  of  freeboard  (See
Figure 8, page 4.) If the pH is 7.0 or greater, media does not
need to be added. If the pH is below 7.0 and/or the amount
of freeboard is greater than 18" for IC-10A or 17" for IC-12A
(see step 5), media needs to be added. If media needs to be
added contact your dealer and ask for the following:
Part Number 1-A8011
.66 cubic foot IC pH Correction Media (50 lb. bag)
TYPE A IRON CURTAIN
SYSTEMS (Optional)
IC-10
10"x54"
1.5
3/4"
5.0
5.0
26"x70"x16"
IC-10A
10"x54"
1.5
3/4"
5.0
5.0
26"x70"x16"
IC-10+
10"x54"
1.5
3/4"
5.0
5.0
26"x70"x16
IC-12
12"x52"
2.0
1"
7.0
8.0
30"x68"x18"
IC-12A
12"x52"
2.0
1"
7.0
8.0
30"x68"x18"
IC-12+
12"x52"
2.0
1"
7.0
8.0
30"x68"X18"
Model
Filter &
Aeration
Tank
Size
Floor
Space
(WxHxD)
(2) Back-
wash
Rate
GPM
Max.
Service
Flow
GPM
(1)
Inlet/
Outlet
Media
Cu. Ft
(1) Aeration Head and Check Valve have 1” Inlet/Outlet.
(2) Water temps above 60
°
 F will require a higher backwash rate. Consult factory.