Hanna Instruments TV Converter Box C 221 Leaflet

Page of 2
Instruction Manual
C 221
Honey Color Analyzer
This Instrument is in
Compliance with the CE Directives
Please examine this product carefully. Make sure that the
instrument is not damaged. If any damage occurred during
shipment, please notify your Dealer.
Each 
C 221 Honey Color Analyzer is supplied complete with:
• Five Sample Cuvets
• 12 VDC Transformer
• One Light Shield Cap
(HI 710005 or HI 710006)
• One support for cuvets
• 30 mL Glycerol (1 bottle)
• Instruction Manual
• Two 9V Batteries
Note: save all packing material until you are sure that the
instrument works correctly. Any defective item must
be returned in its original packing.
Dear Customer,
Thank you for choosing a Hanna product. This manual will provide you
with the necessary information for the correct use of the instrument.
Please read it carefully before using the analyzer. If you need additional
technical information, do not hesitate to e-mail us at
tech@hannainst.com or call 1-800-426-6287.
This instrument is in compliance with 
 directives.
Preliminary Examination
General Description
The 
C 221 portable microprocessor analyzer measures the
percent light transmittance of honey compared to analytical
reagent grade glycerol. The transmittance value allows
identification of the honey Pfund grade. The instrument
directly displays the measurement result expressed in mm
Pfund.
Measurements are made using matched square optical
cuvets having a 10 mm light path.
Display codes aid the user in routine operations.
The meters have an auto-shut off feature that will turn the
instrument off after 10 minutes of non-use.
SPECIFICATIONS
Range
0 to 150 mm Pfund
Resolution
1 mm Pfund
Precision
±2 mm Pfund @ 80 mm Pfund
Typical EMC Dev. 1 mm Pfund
Light Source
Tungsten lamp with narrow band interference
filters @ 420 nm and 525 nm.
Method
Direct Measurement
Light Detector
Silicon Photocell
Environment
0 to 50°C (32 to 122°F);
max 90% RH non-condensing
Power supply
2 x 9V batteries / 12 to 20 VDC through voltage
adapter
Auto-Shut off
After 10' of non-use
Dimensions
230 x 165 x 70 mm (9.0 x 6.5 x 2.8")
Weight
640 g (22.6 oz.)
REQUIRED STANDARD
Description
Quantity/test
Glycerol
4 mL
Warranty
C 221 is warranted for two years against defects in workmanship and
materials when used for its intended purpose and maintained according
to the instructions.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered.
If service is required, contact your dealer. If under warranty, report the
model number, date of purchase, serial number and the nature of the
failure. If the repair is not covered by the warranty, you will be notified
of the charges incurred.
If the instrument is to be returned to Hanna Instruments, first obtain a
Returned Goods Authorization Number from the Customer Service
department and then send it with shipment costs prepaid. When shipping
any instrument, make sure it is properly packaged for complete
protection.
To validate your warranty, fill out and return the enclosed warranty card
within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments
Inc., Woonsocket, Rhode Island, 02895 , USA.
Hanna Instruments reserves the right to modify the design, construction
and appearance of its products without advance notice.
FRONT PANEL
1) Cuvet Holder
2) Dual Level Liquid Crystal Display (LCD)
3) READ key, to perform measurement
4) CAL key, to calibrate the meter prior to measurement
5) ON/OFF key, to turn the meter on and off
REAR PANEL
1) Power Supply 12 VDC 2.5 Watt
2) RS 232 Socket
3) Batteries Compartment
Sampling in progress. This flashing
prompt appears each time the meter is
performing a measurement.
The microprocessor is adjusting the light
level, indicated by a scrolling "SIP".
This indicates that the meter has been
calibrated and measurement can be
performed.
The blinking "LOBAT" indicates that the
battery voltage is getting low and the
batteries need to be replaced.
This indicates that the meter is in a ready
state and zeroing can be performed.
This indicates that the batteries are dead
and must be replaced.
Light over range. The cuvet is not inserted
correctly and an excess ambient light is
reaching the detector. If the cap is properly
installed, then contact  your dealer or the
nearest Hanna Customer Service Center.
This indicates that the meter has lost its
configuration. Contact your dealer or the
nearest Hanna Customer Service Center.
The lamp is not working properly. Contact
your dealer or the nearest Hanna Customer
Service Center.
The lamp is not working properly. Contact
your dealer or the nearest Hanna Customer
Service Center.
ERROR MESSAGES
a) on zero reading:
This indicates that the zeroing procedure
failed due to a low signal-to-noise ratio. In
this case press CAL again.
Honey color varies naturally in a wide range of tonalities,
ranging from light yellow to amber, dark amber and black in
extreme cases; sometimes green or red hues may also occur.
Color of untreated honey depends on botanical origin: for this
reason color is very important for definition and commercial
classification of monofloral honeys. Honey darkens with ageing,
and other changes in color may result from beekeeper’s
interventions and from the different ways of conservation (e.g.:
use of old honeycombs, contact with metals, high temperatures,
exposition to light, etc.).
The primary characteristic for commercial honey classification is
color. Color classes are expressed in millimeters (mm) Pfund
grades, compared to an analytical grade Glycerol Standard
Reference.
Table 1 reports the USDA classification for honey samples and
the related mm Pfund values.
Table 2 shows the color of different monofloral honeys: data are
obtained from a statistical set of honey samples. The table
reports for each type of honey: average value of color, standard
deviation, and the minimum and maximum values measured.
w w w . h a n n a i n s t . c o m
Significance and Use
Specifications
Guide to Display Codes
The instrument cannot adjust the light
level. Please check that the sample does not
contain any debris.