Haier AU282XHERA User Manual

Page of 20
14
3. Wiring method of outdoor unit:
Loosen wire cover and connect the power line and communication wire of indoor unit to the
terminal correspondingly.
Note:
When connecting power line to power supply terminal, please pay attention  to  the  following items:
     Do not connect the power line with different dimensions to the same connection wire end.
     Improper contact will cause heat generation.
     Do not connect the power line with different dimensions to the same grounding wire end.
     Improper contact will affect protection.
     Keep a proper distance between the  communication wire and the power line. Otherwise, abnormal
     communication will occur because of disturbance. And also, the communication wires should be
     shielded wire, and the shield cover should be grounded on the outdoor unit.
     Do not connect the  power  line  to  the  connecting end of communication wire.
     Incorrect connection will cause damage to the connected unit.
4. Wiring method of indoor unit
Crimp connection method for connection wire
After connection,the wire must be fastened by wire cover. The wire cover shall press on the protection
coat of the connection wire,as shown in right top figure.
Note:When connecting the wiring,confirm  the  terminal number of indoor and outdoor units carefully.
Incorrect wiring will damage the controller of air conditioner or the unit can not operate.
Wiring work
Power line
Remove the repair board of the outdoor unit and loosen the wire cover A,then put the live wire, neutral
wire  and  grounding  wire  through  the  wire  cover ,and connect them to  terminal block correspon
dingly. After connection, fasten  wire  cover  to  its  previous state.
Communication wire of  indoor  unit.
Loosen wire cover , put the communication wire through the wire cover  B, and  connect  them to
terminal block correspondingly.  After  connection,  fasten  wire cover  B  to its previous state.
Note: Power line and communication  wire  are provided  by consumers themselves.
Terminal block
Cord anchorage A
Cord anchorage B
Valve cover