Fan and Heater
TRANSITION HI-LIMIT INSTALLATION
1. Mark location on transition
one (1) foot up from the bot-
tom (entrance collar) and cen-
tered in the transition.
2. Drill or knock out 7/8" diam-
eter  hole on marked location.
3. Install transition hi-limit us-
ing supplied self drilling
screws.
Figure 2: The transition connecting the Vane Axial Heater to the bin with
the plenum sensor in place.
Plenum Thermostat
Mounting
The plenum thermostat is the 4 x
4 white box with knob that is
preconnected to heater when
heater is ordered with thermostat.
1. 24" to the right side of the
transition, drill one
 3
/
8
" hole
(high temp) or 1 
1
/
2
" hole (low
temp) in the center of the ple-
num in a valley (4.00" corru-
gation) or hill (2.66" corruga-
tion) on bin sidewall.
2. Insert the probe through the
hole.
3. Position the housing so that
the tabs are vertical, and the
cord exits the housing hori-
zontally.
Plenum thermostat mounting on bin wall.
5. Caulk between the housing
and the sidewall to seal.
4. Use 4 self drilling screws to
mount the housing to the bin
sidewall.