NOTE: 
Path cost "0" is used to indicate auto-configuration mode. When the short path 
cost method is selected and the default path cost recommended by the IEEE 8021w 
standard exceeds 65,535, the default is set to 65,535.  
By default, the system automatically detects the speed and duplex mode used on 
each port, and configures the path cost according to the values shown below. 
Table 4-1: Recommended STP Path Cost Range 
Port Type 
IEEE 802.1D-1998 
IEEE 802.1w-2001  
Ethernet 
50-600 200,000-20,000,000 
 
Fast Ethernet 
10-60 20,000-2,000,000 
 
Gigabit Ethernet 
3-10 2,000-200,000 
 
Table 4-2: Recommended STP Path Cost Range 
Port Type 
Link Type 
IEEE 802.1D-1998 
IEEE 802.1w-2001  
Ethernet 
Half Duplex 
Full Duplex 
Trunk 
100  
95  
90 
2,000,000  
1,999,999  
1,000,000 
Fast Ethernet 
Half Duplex 
Full Duplex 
Trunk 
19  
18  
15 
200,000 
100,000 
50,000 
Gigabit Ethernet 
Full Duplex 
Trunk 
4  
10,000 
5,000