Goldline LOGIC PL-P-4 User Manual

Page of 36
Gallons and (Liters) of Pool/Spa water
12,000 14,000 16,000 18,000 20,000 22,000
32,000
24,000
34,000
26,000
36,000
28,000
38,000
30,000
40,000
Current salt 
level
(45000) (52,500) (60,000) (67,500) (75,000) (82,500)
(120,000)
(90,000)
(127,500)
(97,500)
(135,000)
(105,000)
(142,500)
(112,500)
(150,000)
ppm
0
320    
(145)
373   
(170)
427   
(194)
480   
(218)
(242)
587   
854   
(267)
(388)
640   
907   
(291)
(412)
693   
960   
(315)
(436)
747    
(339)
(460)
800    
1067
(364)
(484)
200
300   
(136)
350   
(159)
400   
(182)
450   
(205)
500   
(227)
550   
800  
(250)
(363)
600   
850   
(273)
(385)
650   
900  
(295)
(408)
700    
950 
(318)
(430)
750    
1000 
(341)
(453)
400
280   
(127)
327  
(148)
373   
(170)
420   
(191)
467   
(212)
513   
747   
(233)  
(339)  
560   
793   
(255)
(360)
607   
840   
(276)
(382)
653    
887
(297)
(403)
700    
933
(318)
(424)
600
260   
(118)
303  
(138)
347    
(158)
390   
(177)
433   
(197)
477   
693   
(217)
(317)
520   
737   
(236)
(337)
563   
780   
(256)
(358)
607    
823
(276)
(378)
650    
867
(297)
(398)
800
240   
(109)
280   
(127)
320   
(145)
360    
(164)
400   
(182)
440   
640  
(200)
(291)
480   
680   
(218)
(310)
520  
720  
(236)
(328)
560    
760
(255)
(346)
600    
800    
(273)
(364)
1000
220   
(100)
257   
(117)
293   
(133)
330   
(150)
367   
(167)
403   
587   
(183)
(267)
440   
623  
(200)
(283)
477   
660
(217)
(300)
513     
697
(233)
(317)
550    
733
(250)
(333)
1200
200   
(91)
233   
(106)
267   
(121)
300   
(136)
333   
(152)
367   
533   
(167)
(243)
400    
567   
(182)
(258)
433   
600   
(197)
(274)
467     
633
(212)
(289)
500    
667
(227)
(304)
1400
180   
(82)
210   
(95)
240   
(109)
270   
(123)
300   
(136)
330   
480 
(150)
(218)
360   
510   
(164)
(232)
390   
540   
(177)
(246)
420     
570
(191)
(259)
450    
600
(205)
(263)
1600
160     
(73)
187   
(85)
213   
(97)
240   
(109)
267   
(121)
293   
427   
(133)
(195)
320   
453  
(145)
(207)
347   
480   
(158)
(219)
373    
507 
(170)
(231)
400    
533
(182)
(243)
1800
140     
(64)
163     
(74)
187     
(85)
210   
(95)
233   
(106)
257   
373  
(117)
(169)
280   
397   
(127)
(180)
303   
420   
(138)
(190)
327      
443 
(148)
(201)
350      
467
(159)
(211)
2000
120     
100     
80     
60     
20     
40     
(55)
(45)
(36)
(27)
(9)
(18)
140     
117     
23     
47    
(64)
(53)
(11)
(21)
160     
133     
27     
53     
(73)
(61)
(12)
(24)
180     
150     
30     
60    
(82)
(68)
(14)
(27)
200     
167     
33     
67     
(91)
(76)
(15)
(30)
220     
320     
183     
267     
37     
53     
73     
107   
(100)
(145)
(83)
(121)
(17)
(24)
(33)
(48)
240     
340    
200     
283   
40     
57     
80     
113   
(109)
(154)
(91)
(129)
(18)
(26)
(36)
(51)
260   
360   
217   
300   
43   
60
   
87   
120   
(118)
(163)
(98)
(137)
(20)
(27)
(39)
(54)
280      
380
233      
317
47      
63
93      
127
(127)
(172)
(106)
(144)
(21)
(29)
(42)
(57)
300      
400 
250      
333
50      
67 
100      
133
(136)
(181)
(114)
(152)
(23)
(30)
(45)
(60)
(32)
80     
(36)
90     
(41)
100     
(45)
110     
160     
(50)
(73)
120     
170   
(55)
(77)
130   
180   
(59)
(81)
140      
190
(64)
(86)
150      
200
(68)
(90)
93     
(42)
107     
(48)
120     
(55)
133     
(61)
147     
213     
(67)
(98)
160     
227   
(73)
(104)
173   
240  
(79)
(110)
187      
253 
(85)
(117)
200      
267
(91)
(123)
2200
3000
2800
2400
3200
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
Ideal
2600
3400
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM
3600+
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
Dilute
10,000
 8,000
(37,500)
213     267    
(97)
(121)
200    250   
(91)
(114)
187    233   
(85)
(106)
173    217   
(79)
(98)
160    200   
(73)
(91)
147    183   
(67)
(83)
133    167   
(61)
(76)
120    150   
(55)
(68)
107      133     
(48)
(61)
93      117     
(42)
(53)
80      100     
67      83     
53      67     
40    
50     
13      17     
27      33     
(36)
(45)
(30)
(38)
(24)
(30)
(18)
(23)
(6)
(8)
(12)
(15)
Ideal
Ideal
Dilute
Dilute
(30,000)
3
The pool’s chemistry must be balanced BEFORE activating the Pro Logic’s optional chlorinator function.  NOTE:  If
the pool does not have new water, add metal remover and non-copper based algaecide to the pool, per manufacturer’s
instructions.  This ensures a quick, troublefree transfer to the Pro Logic system.
Salt 
(When using optional chlorinator function )
Salt Level
Use the chart on the top of page 4 to determine how much salt in pounds or (Kgs) should be added to reach the
recommended levels.  Use the Pool Sizing Formula on page 4 (measurements are in feet/gallons and meters/liters) if
pool size is unknown.
The operating salt level is between 2700-3400 PPM (parts per million) with 3200 PPM being optimal.  Before adding
any salt, test the salt level.  This is especially important for retrofit installation to older pools where all of the chlorine
added to the pool over time is ending up as salt.  If the level is low, determine the number of gallons in the pool and add
salt according to the chart below.  A low salt level will reduce the efficiency of the sanitization and result in low chlorine
production.  A high salt level can cause the Pro Logic to stop chlorinating.  The salt in your pool/spa is constantly
recycled and the loss of salt throughout the swimming season should be minimal.  This loss is due primarily to the
addition of water because of splashing, backwashing, or draining (because of rain).  Salt is not lost due to evaporation.
28
Valve3 Interlock
If “Enabled”, this feature will override the function (timeclock or in-floor cleaner) selected above and turn
the valve off when:  the filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime
and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar panels to be
purged).   Interlock is not available for solar or super chlorinate.
Valve3 External Input Interlock
When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external
input is active.  This will have precedence over freeze protection. Valve3 External Input Interlock is not
available for solar and super chlorinate.
Valve3 Freeze Protection
This function protects the pool and plumbed equipment against freeze damage.  If Freeze Protection is
enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold, the Pro
Logic will turn on the valve to allow circulation of the water.  IMPORTANT:  this only enables operation of
the valve3 output during freeze--see the “Filter Pump Config.” menu to enable freeze protection for the
main circulation system.
6B Spa Config.
+ to view/change
6B A,  Button 1
Pool/Spa
Select 6B Spa
A
Push to access the 6 Button Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, 
Aux1 and Aux2
Rotates between all available remotes
Move to previous/next configuration menu 
Move to previous/next menu item or next configuration menu
Move to next menu item
if AQL-SS-6B is connected
Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up.  Select which of the available
remote controls (A, B or C) is to be configured.
6B A,  Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Pro Logic
functions.  The default selections are:  Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button 4 -
Heater1, Button 5 - Aux1 and Button 6 - Aux2.
Remote Menus
Enabled
Toggle between Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu
This feature will prevent unauthorized access to the Settings, Timers, and Configuration menus from any
of the Pro Logic’s remote display/keypads.  When disabled, the remote display/keypads will only show the
default menu and allow on/off control via the pushbuttons.  Note that the function of the Pro Logic’s built-
in display/keypad is unchanged by this selection.  Once disabled, the only way to enable “Remote
Menus” is to use the local display/keypad.
All Timeclocks 
7-day
Move to previous/next configuration menu 
Toggle between 7-day (default) and Weekend/Weekday time options
This selection affects ALL of the timeclock logic in the Pro Logic.  If  “7-day” is selected, each timeclock will
have one set of turn-on/turn-off settings that operate every day of the week.  If “Weekend/Weekdays”
option is selected then the user can enter one set of turn-on/turn-off times for the weekend (fixed as
Saturday/Sunday) and another set of turn-on/turn-off times for weekdays (Monday through Friday).