In rare cases an N-Ring can have a “Partial Fault”.  An example of this is to have a break in just one fiber in 
a duplex channel fiber pair.  The screenshot below shows N-Ring Manager Status when a ‘Higher’ N-Ring 
Port (GB2 or FX2) is not receiving self health frames all the way around the N-Ring, though the other (low 
GB1/FX1) N-Ring port is: 
 
N-Ring Partial Fault (GB2 is not receiving self health from GB1) 
 
N-Ring Status View 
 
Switch is an N-Ring Manager, using N-Ring Aging Time = 20 seconds 
Refresh every 
6
 secs. 
   
Update
        
Pause
       
Print...
   
 
0 Active Members Detected In Current N-Ring (0 reporting)  
Switch No MAC Address 
IP Address 
Subnet Mask  Name 
Ports 
RM 
00:07:af:00:b1:40
 192.168.1.135 255.255.255.0 N-TRON Switch 
GB2 
GB1 
 
 
 
The screenshot below shows N-Ring Manager Status when a ‘Lower’ N-Ring Port (GB1 or FX1) is not 
receiving self health frames all the way around the N-Ring, though the other (high GB2/FX2) N-Ring port 
is: 
 
N-Ring Partial Fault (GB1 is not receiving self health from GB2) 
 