• For retrofit, place LED driver in the location where the ballast was formerly located. 
• Make output (DC) connections as noted below:
• Make input (AC) connections using one of the two options below:
• The LED Driver is required to be reliably bonded to the protective ground conductor.
Connect LED Driver - Output
Connect LED Driver - Input
Dimming /Occupancy Sensor Contacts – Output (Optional)
OPTION 1 (OEM) – USING 2-WAY CONNECTOR
OPTION 1 (OEM) - USING 2-WAY CONNECTOR
Connection of Dimming Control:
OPTION 2 (OEM) – USING TWIST-ON WIRE CONNECTORS
OPTION 2 (OEM) – USING TWIST-ON WIRE CONNECTOR
1
2
3
• To enable dimming operation and/or occupancy sensors you must connect leads from occupancy sensor or control system  
  (normally open contact) to the purple and gray leads of the power supply and adjust dimming switch as shown below.
Note: connection of occupancy sensor to the dimming leads will reduce light output to 20% normal output.
• Make output (contact closure) connections as noted below:
A
B
C
C
Connect the LED Driver output leads to the LED 
Light leads using the appropriate mating connector 
(Tyco p/n 794896-1). Terminals installed should be 
crimped using approved tooling and process per 
Molex specifications. Ensure that the connector 
cavities are correctly populated per the wire colors 
shown on page 3.
Ground driver to metal portion of the door frame. 
Connect the original Line and neutral wires (or 
Line 1 and Line 2 wires for 240 nominal VAC) to the 
2-way connector for the LED Driver input wires 
using the appropriate mating connector (JST p/n 
VLR-02V). Ensure that the connector cavities are 
correctly populated per the wire colors on page 3.
Ground driver to metal portion of the door frame. 
Remove the 2-way connector from the LED Driver 
by cutting the wires near the connector and strip 
the input wires. Using the appropriate wiring 
diagram on page 3, connect the original Line and 
neutral wires (or Line 1 and Line 2 wires for 240 
nominal VAC) to the LED Driver leads using twist 
lock wire connectors or other connection method 
approved for low temperature usage and stranded 
cable. 
A
Remove the 2-way connector from the LED Driver 
by cutting the wires near the connector and strip 
the output leads. Using the appropriate wiring 
diagram on page 3, connect the LED Driver output 
leads to the LED Light leads using wire connectors 
or other connection method approved for low 
temperature usage and stranded cable.
For non-dimming applications, cap the unused 
wires with 5/32” (4mm) twist on wire connectors. 
For Retrofit: Bundle and safely secure any unused 
wires by way of approved wire ties and wire 
connectors.
Connect the LED Driver dimming output leads to 
the occupancy sensor or control system using wire 
connectors or other connection method approved 
for low temperature usage and stranded cable.
•  The GEPS6000NCCON-SY LED Driver is capable of 
step dimming from 100% power to 20% power 
when used with a normally open contact closure 
occupancy sensor system. 
•  When using the GEPS6000NCCON-SY for dimming  
applications, the dimming switch setting must be 
switched to the left to enable the dimming feature. 
The following is the only recommended usage of 
occupancy sensors with the  
 
Immersion LED lighting system. Other methods, such 
as using occupancy sensors to switch the LED driver 
on and off is not recommended and will void the 
product warranty.