Command and Response table for basic SIS commands (continued)
Command
ASCII command
(host to device)
Response
(device to host)
Additional description
Presets, I/O Names
Write preset name
EX1)
,
X1!
NG
}
Nmg
X1)
,
X1!]
Example:
E
1,Security1NG
}
Nmg
01
,Security1
]
Name preset 1 “Security 1”
Read preset name
EX1)
NG
}
X1!]
Example:
E
2NG
}
Security2
]
Recall a preset
X1)
.
Rpr
X1)]
Command character is a 
period
.
Example
5
.
Rpr
X1)]
Recall preset 5, which 
becomes the current 
configuration.
Write input name
EX#
,
X1!
NI
}
Nmi
X#
,
X1!]
Example:
E
9,Podium cam1NI
}
Nmi
0
9,Podium cam1
]
Name input 9 “Podium cam1”
Read input name
EX#
NI
}
X1!]
Write output name
EX@
,
X1!
NO
}
Nmo
X@
,
X1!]
Example:
E
1,Main PJ1NO
}
Nmo
0
1,Main PJ1
]
Name output 1 “Main PJ1”
Read output name
EX@
NO
}
X1!]
Resets
Reset presets and names
E
ZG
}
Zpg
]
Clear all presets and their 
names.
Reset an individual preset
EX1)
ZG
}
Zpg
X1)]
Clear preset 
X1)
.
Reset a group
E
Z
X2)
GRPM
}
GrpmZ
X2)]
Delete all members from 
group 
X2)
, reset parameters 
and soft limits.
NOTE:  See 
 on page 69, for more information about audio group masters.
Reset flash
E
ZFFF
}
Zpf
]
Reset flash memory 
(erase user-supplied files).
System Reset (factory 
defaults)
E
ZXXX
}
Zpx
]
Resets all processors, level 
controls and mixers to default.
Reset all device settings 
and delete files
E
ZY
}
Zpy
]
NOTE:  This reset excludes IP settings such as IP address, subnet mask, gateway IP address, unit name, DHCP setting and 
port mapping (telnet/web/direct access) in order to preserve communication with the device.  
This reset is recommended after a firmware update.
Absolute reset
E
ZQQQ
}
Zpq
]
Similar to 
System Reset
plus sets the IP address 
to 
192.168.254.254
 
and the subnet mask to 
255.255.0.0
.
NOTES: 
X#
 = Input number 
 
01 – 06
 
X@
 = Output number 
 
01 – 04
 
 
X1)
 = Preset #   
 
32 maximum (
0
 = current configuration)
 
X1!
 = Name 
 
 
12 characters maximum
 
X2)
 = Group master group number 
01 – 32
 
DMP 64 • SIS Programming and Control
102