Extron electronic Extron Electronics Music Mixer DMP 44 LC User Manual

Page of 81
Error Responses
When the DMP 44 LC is unable to execute the command, it returns an error response to 
the host. The error response codes and their descriptions are as follows:
Code
Description
E10
Invalid command
E11 
Invalid preset
E12 
Invalid port number
E13 
Invalid parameter (number is out of range)
E14 
Not valid for this configuration
E17 
System timed out
E22 
Busy
E25
Device is not present
Command/Response Table Overview
Although the DMP 44 LC uses the same structure for SIS commands, there are two 
variations. One is the global command structure documented in the  
The second set of tables for DSP SIS commands uses the command structure outline 
beginning with 
. While using the 
same structure of basic SIS commands, they differ in how the software addresses the 
individual processor blocks within the DMP 44 LC. 
Command/Response Table for Basic SIS Commands
Symbol definitions
]
=
CR/LF (carriage return/line feed) (hex 0D 0A)
}
=
Carriage return (no line feed, hex 0D) 
=
Space character
|
=
Pipe (vertical bar) character
E
=
Escape key (hex 1B)
=
=
Future capability (not currently available)
X!
= Version number
Listed to two decimal places (for example, x.xx)
X@
= Version and Build number
The least significant bits is the build number (for example, x.xx.xxxx)
X#
= Verbose/Response mode
0 = clear or none
1 = verbose mode (not tagged, not broadcast)
2 = tagged responses for queries (taggednot broadcast)
3 = verbose mode + tagged responses for queries (tagged and broadcast)
Default = 1 for RS-232 host control
NOTE: 
If ‘tagged responses’ is enabled, all read commands will return the 
constant string + the data, like setting the value does, for example,  
command:
 
 
ECN}
 
response:
  
Ipn•X1@]
X$
= Baud rate
0 = 9600 
1 = 19200 
2 = 38400 (default) 
3 = 15200
 
DMP 44 LC • SIS Programming and Control