Command/Response Tables for Audio SIS Commands
DSP control commands are an extension to SIS commands. They differ only in their data 
string and the requirement to send each command with an “Au” suffix.  
Symbol definitions
]
=
CR/LF (carriage return/line feed) (hex 0D 0A)
}
=
Carriage return (no line feed, hex 0D)  
(use the pipe character, 
|
 , for Web browser commands))
=
Space character
|
=
Pipe (vertical bar) character
E
=
Escape key (hex 1B)  (use W instead of Esc for Web browsers)
NOTE:  The dB values of the level settings are in 0.1 dB increments using negative numbers but not decimal 
places. Multiply the desired level setting by ten for the SIS command value. 
Example: To set an input level to 45.2 dB, use 452. To set an input level to -12.5 dB, use -125.
X6)
= Gain and trim control or mix-point select
See “
.
X6!
= Level value in dB;  
dB value, in 0.1 dB increments using negative numbers but not decimal 
places. The valid range depends on the type of gain block specified in the 
X6)
 
command: The valid range depends on the control or mix-point.
a
 = –180 to 240 (–18 to +24 dB)
b
 = –1000 to 60 (–100 to +6.0 dB)
c
 = –240 to 120 (–24 to +12 dB)
d
 = –120 to 60 (–12 to +6.0 dB)
e
 = –1000 to 0 (–100 to 0.0 dB)
X6@
= Input Polarity
0 = Standard 
1 = Inverted
X6$
= Mute status
0 = unmute 
1 = mute
X6%
= Group master group number
01 – 16 
X6^
= Group fader setting
dB value, in 0.1 dB increments using negative numbers but not decimal places.  
The valid range depends on the type of gain block that is assigned to the group 
number (
X6%
) specified in the command: 
a
 = -180 to 800  (-18.0 dB to +80.0 dB) 
b
 = -1000 to 120  (-100.0 dB to +12.0 dB) 
c
 = -350 to 250  (-35.0 dB to + 25.0 dB) 
d
 = -120 to 120  (-12.0 dB to +12.0 dB) 
e
 = -1000 to 000  (-100.0 dB to +0.0 dB)
NOTE: 
Leading zeros are ignored.
X6&
= Group fader increment
dB value, in 0.1 dB increments, to raise or lower a group fader
X6*
= Group fader soft limit
dB value, in 0.1 dB increments.  The valid range 
X6^
 must be within the range 
for the gain block grouped in 
X6%
.
X6(
= Group type
  6 = gain 
12 = mute
X7)
= Personal Identification Number (PIN)
Four numeric digits, default = 0000
 
DMP 44 LC • SIS Programming and Control