Epson V7 User Manual

Page of 344
3
6. V-Link
3-21
Ser
6.
V-Link
V-Link
• “V-Link” is the network where the computer reads from and writes to the internal 
memory of the V7 series, memory card, PLC memory or temperature control/PLC2 
memory using a dedicated protocol.
• Use the MJ port of the V7 series for connection with a general-purpose computer.  For 
connection with the PLC using a temperature controller or the PLC2Way function, use 
the other MJ port and use CN1 for communications with the PLC.  Data of the PLC or 
temperature controller can be collected through communications with the V7 series.  
Data collection is available even between the products of different manufacturers.
• Either signal level RS-232C or RS-485 can be selected.  With RS-232C, one V7 series 
can be connected; with RS-485, a maximum of 31 V7 series can be connected.
<RS-485 connection>
PLC
PC
RESET
disc
F1
F2
F3
F4
F5
F6
F7
SYSTEM
POWER
V7 series
Dedicated commands
Read
Write
PLC
RS-232C
RS-422
RS-485
PLC
PLC
RS-485
RS-232C
RS-422
RS-485
CN1
CN1
CN1
MJ2
MJ2/1
MJ2/1
MJ1
RESET
disc
F1
F2
F3
F4
F5
F6
F7
SYSTEM
POWER
F1
F2
F3
F4
F5
F6
F7
SYSTEM
POWER
F1
F2
F3
F4
F5
F6
F7
SYSTEM
POWER
Temperature controller 
inverter or PLC
Local 
Port 1
Local 
Port 2
Local 
Port 31