Emerson Liebert PSA Line-Interactive UPS 500-1500VA User Manual

Page of 120
What is Required to Use Liebert MultiLink?
6
Liebert
®
 MutiLink
®
3.2
Requirements for Installing Liebert MultiLink
Before beginning installation, review these requirements and follow Steps 1 through 3 below.
The prospective user must have:
• The Liebert MultiLink software—Advanced or Fundamental; Advanced is available on CD; 
Fundamental is downloadable at:
Visit the Web site or contact your local Emerson representative, value-added reseller, or 
distributor for information.
• This manual—downloadable from the Liebert MultiLink Web site:
• A Liebert UPS linked to a computer.
• For requirements specific to various operating systems, see the Liebert MultiLink Web site,
• A communications link between the UPS and the computer, depending on the type of connection:
• With an SNMP card in the UPS, an available IP port—either 161 and 162 or Liebert-reserved 
ports 3027 and 3029—depending on your operating system and configuration (see 
• TCP/IP connectivity throughout the network, if the UPS is equipped with an SNMP card or if 
Liebert MultiLink will monitor or communicate with more than one UPS or computer.
Before beginning installation:
1. Check with your System Administrator about the need to disable certain network software (see 
2. For a serial port connection to the UPS, you will need to buy or make a custom cable. Liebert 
MultiLink will NOT function properly with an ordinary serial cable connected to the UPS. 
• You may purchase a cable by contacting your local Emerson representative, value-added 
reseller or distributor (see Appendix E - Ordering Parts for part numbers). 
3. For configurations in which the source of events is to be a UPS with an SNMP agent, be sure to 
include the IP address of the computer(s) on which Liebert MultiLink is to be installed in the 
SNMP agent’s list of trap recipients. This speeds notifications about the UPS’s condition to the 
computer.
Connection Type
Link Between UPS and Computer
Contact Closure
(Same as Serial Communications)
• A special serial cable—available from Liebert or built with instructions in 
• An available serial port on the computer protected by the UPS (see 
USB 
(if the UPS has
a USB port)
• A USB cable with a Type A connector on one end (to connect to the computer) and a 
Type B connector on the other (to connect to the UPS)
• An available USB port—or an adapter from the computer’s serial port to the Type A 
connector end of the USB cable—on the computer protected by the UPS
Serial 
Communications
(Same as Contact Closure)
• A special serial cable—available from Liebert or built with instructions in 
• An available serial port on the computer protected by the UPS (see 
SNMP
• Ethernet, Internet or Intranet, utilizing SNMP protocol and IP addresses