Emerson Liebert PSA Line-Interactive UPS 500-1500VA User Manual

Page of 120
Configuring Liebert MultiLink for Your System
67
Liebert
®
 MutiLink
®
8.5.6 Event Actions - Command (Liebert MultiLink Advanced Only)
The Command feature allows the System Administrator to control applications that have 
command-line options, for example, to save files or close an application.
To configure the Command action:
• Check  (
) the Enable Command Action box. This is required for the action to operate.
• Use the arrows in the Initial Delay boxes to specify the time lapse between an event’s occurrence 
and when the command is executed.
• In  the  Properties line, specify a command by either typing it in the Command box or by clicking 
on the Browse button and locating the appropriate file.
• In  the  Arguments box, enter any arguments required for the command to function properly. 
Once entered, arguments will remain in the Arguments box until deleted. If inappropriate 
arguments are displayed, be sure to delete them.
• The Canceling Event will abort all actions initiated by Liebert MultiLink in response to the 
event being configured. SeTable 14 for a list of Events with default canceling events.
• At any time, click on the Reset to Defaults button to revert to the factory defaults for this 
feature.
• To save settings, click on the MultiLink menu at the top of the window, then click on Save 
Event Configuration.
Enable 
box
Command Action