43
Table 14
Battery run time, minutes
Number of
Batteries
Load Percent
of Capacity
208/120VAC RT
208VAC RT
220VAC Tower
5kVA
6kVA
8kVA
10kVA
6kVA  (L630)
10kVA
Internal Battery
10
108
94
128
100
100
81
20
49
43
61
46
50
39
30
34
26
40
28
38
22
40
22
17
27
18
26
15
50
16
13
20
14
19
11
60
13
10
16
11
15
8
70
11
8
13
9
12
6
80
9
6
11
7
10
5
90
7
5
9
6
9
4
100
6
4
7
5
8
3
Internal Battery
+ 1 External
Battery Cabinet
10
164
154
192
159
164
190
20
110
96
129
102
102
127
30
74
53
90
65
74
81
40
50
44
63
46
51
60
50
42
34
48
37
45
46
60
34
26
41
28
38
39
70
27
21
34
23
31
32
80
22
17
27
18
25
26
90
18
15
23
16
22
22
100
16
13
20
14
19
18
Internal Battery
+ 2 External
Battery Cabinets
10
221
201
308
210
209
316
20
149
136
158
141
136
162
30
112
97
130
103
103
136
40
82
69
101
74
82
106
50
66
50
77
52
67
82
60
50
44
63
46
51
69
70
45
37
50
40
47
52
80
39
31
45
34
42
48
90
34
26
40
28
38
44
100
28
22
36
25
33
39
Internal Battery
+ 3 External
Battery Cabinets
10
318
304
330
310
226
20
165
156
194
160
180
30
142
127
152
133
124
40
112
97
131
103
104
50
94
74
107
79
92
60
75
60
91
65
74
70
62
49
74
51
62
80
50
44
63
46
51
90
46
39
51
42
48
100
42
34
47
37
44
Internal Battery
+ 4 External
Battery Cabinets
10
334
322
343
327
360
20
203
180
220
190
199
30
156
145
164
149
152
40
137
122
148
128
113
50
113
98
131
103
104
60
98
77
110
82
94
70
79
66
97
71
79
80
69
52
80
60
69
90
53
48
71
50
60
100
50
44
63
46
51