EMC DS-16B2 User Manual
1
Configuring the IP Address
1-5
Setting the Initial Switch Configuration
Configuring the IP Address
The Departmental Switch DS-16B2 switch is shipped with a default
IP address of
IP address of
10.77.77.77.
To change the default IP Address and configure the Fibre Channel IP
address of the switch:
address of the switch:
1. Login to the switch as the admin user.
2. At the command line, enter the following command:
ipAddrSet
3. An interactive session opens and prompts you for configuration
values.
a. Press
E
NTER
without entering a value to skip over a prompt and
leave the parameter value as the default.
b. At the
Ethernet
IP
Address
prompt, enter the new IP address
for the Ethernet port on the switch. Press
E
NTER
to continue.
c. At the
Ethernet
Subnetmask
prompt, enter the address of the
subnetmask, if applicable. Press
E
NTER
to continue.
d. At the
Gateway Address
prompt, enter the IP address of the
gateway system if applicable. Press
E
NTER
to continue.
e. The configuration is then committed to the switch firmware.
f. You are then prompted whether to make the IP address
changes active now or at the next reboot. Enter
y
at the
prompt to have the IP address changes take effect
immediately.
immediately.