EMC CLARiiON AX150 Series User Manual

Page of 1015
36.  Driver Version SAN 4.4.10
37.  Driver Version SAN 4.4.11
38.  Driver Version SAN 4.4.10 Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath. (do not include the quotes on either entry).
Driver version SAN 4.3 or older is not supported for MPxIO on EMC storage arrays.
39.  Driver Version SAN 4.4.11 Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath. (do not include the quotes on either entry).
Driver version SAN 4.3 or older is not supported for MPxIO on EMC storage arrays.
40.  FCode 1.17 is the minimum necessary for boot from SAN.
41.  Veritas DMP coexistence with EMC CLARiiON failover packages:
VERITAS DMP can be enabled and coexist on the same host with ATF or PowerPath.
VERITAS DMP, as part of Volume Manager, can be used to manage CLARiiON arrays without ATF or PowerPath by using CLR−ASL.
42.  Sun "clone" hosts are not supported
43.  FCode Value 2.00 (Flash image 1.69)
44.  FCode Value 1.17 FCode 1.17 is the minimum necessary for boot from SAN. Fcode should be loaded on all HBA's at the time of initial installation. This should only be done before
configuring devices, and should not be done after devices are configured. If HBA does not contain Fcode and Fcode is loaded after devices are configured, the device paths will
change and this could result in loss of data.
45.  Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath. (do not include the quotes on either entry).
Driver version SAN 4.3 or older is not supported for MPxIO on EMC storage arrays.
46.  FCode Value 1.24 (flash image 1.56) Fcode should be loaded on all HBA's at the time of initial installation. This should only be done before configuring devices, and should not be
done after devices are configured. If HBA does not contain Fcode and Fcode is loaded after devices are configured, the device paths will change and this could result in loss of data.
47.  SDS support on Solaris 8 requires minimum SDS version 4.2.1 with patch 108693−16 or later version.
48.  EMC required Sun patches for Solaris 9:
112233−12 SunOS 5.9: kernel patch
117171−17 SunOS 5.9: kernel patch
118558−39 SunOS 5.9: kernel patch
122300−36 SunOS 5.9: Kernel patch
112834−06 SunOS 5.9: patch SCSI
113277−62 SunOS 5.9: sd and ssd patch
119914−14 SunOS 5.9: SAN 4.4.x: Emlxs driver and utility patch
49.  Minimum Supported revision
50.  EMC required Sun patches for Solaris 8:
108528−29 SunOS 5.8: kernel update patch.
117000−05 SunOS 5.8: kernel patch
117350−60 SunOS 5.8: kernel patch
108974−57 SunOS 5.8: data, uata, dad, sd, and scsi patch.
109657−11 SunOS 5.8: isp driver patch (for X1062A and X1065A HBAs only).
109885−20 SunOS 5.8: glm driver patch (for X6541A HBA only).
119913−14 SunOS 5.8: SAN 4.4.x: Emlxs driver and utility patch
51.  For new installations, core software minimum requirement with
CX700
Array software 02.06.700.5.001
CX500
Array software 02.06.500.5.001
CX300
Array software 02.06.300.5.001
CX600
Array software − Access Logix 02.02.1.60.5.005
Array software − Non−Access Logix 02.02.0.60.5.005
CX400
Array software − Access Logix 02.02.1.40.5.006
Array software Non−Access Logix 02.02.0.40.5.006
52.  Must add "set ssd:ssd_max_throttle=20" in /etc/system for Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
53.  Requires Sun patch 125184−02 or later for path failover applications.
Sun Solaris x86
Sun Solaris x86
No.
Host System
Operating System
Host Bus
Host Bus Adapter
Topology
Storage Array
External
Boot
1
Sun Sun Fire
X4100
1
Sun Solaris x86 10 S10 Update 1 (01/06)
3, 4, 5, 6,
7, 8
PCI−X
QLogic QLA2460−E−SP
2, 9, 10,
11, 12, 13, 14
FC−AL,
FC−SW
EMC CLARiiON
AX150
Y
2
Sun Sun Fire
X4600−M2
1
Sun Solaris x86 10 S10 Update 1 (01/06)
3, 4, 5, 6,
7, 8, 15, 16, 17
PCI Express,
PCI−X
QLogic QLA2460−E−SP
2, 9, 10,
11, 12, 13, 14
FC−AL,
FC−SW
EMC CLARiiON
AX150
N
3
Sun Sun Fire
X4600
1
Sun Solaris x86 10 S10 Update 1 (01/06)
3, 4, 5, 6,
7, 8, 15, 16, 17
PCI−X
QLogic QLA2460−E−SP
2, 9, 10,
11, 12, 13, 14
FC−AL,
FC−SW
EMC CLARiiON
AX150
Y
4
Sun Sun Fire:
V20z
1
, V40z
1
Sun Solaris x86 10 S10_x86 Update 1 (01/06)
3, 4,
5, 6, 7, 8, 15, 16, 17
PCI−X
QLogic QLA2460−E−SP
2, 9, 10,
11, 12, 13, 14
FC−AL,
FC−SW
EMC CLARiiON
AX150
Y
5
Sun Sun Fire
X4200−M2
1
Sun Solaris x86 10 S10_x86 Update 1 (01/06)
3, 4,
5, 6, 7, 8, 16
PCI Express,
PCI−X
QLogic QLA2460−E−SP
2, 9, 10,
11, 12, 13, 14
FC−AL,
FC−SW
EMC CLARiiON
AX150
Y
6
Sun Sun Fire
X4200
1
Sun Solaris x86 10 S10_x86 Update 1 (01/06)
3, 4,
5, 6, 7, 8, 16
PCI−X
QLogic QLA2460−E−SP
2, 9, 10,
11, 12, 13, 14
FC−AL,
FC−SW
EMC CLARiiON
AX150
Y
1.  Must add "set sd:sd_io_time=60" and "set sd:sd_max_throttle=20" in the /etc/system file for Symmetrix or CLARiiON attach. Do not include quotes on the entries.
2.  BIOS 1.24 (flash image 1.56)
3.  EMC requires Sun patches for Solaris 10_x86
118855−36 SunOS 5.10_x86: kernel patch
120012−14 SunOS 5.10_x86: Kernel patch
127128−11 SunOS 5.10_x86: Kernel patch
137138−09 SunOS 5.10_x86: Kernel patch
138889−03 SunOS 5.10_x86: Kernel patch
119131−33 SunOS 5.10_x86: Sun fibre channel device drivers
125185−10 SunOS 5.10_x86: Sun Fibre Channel Device Drivers
120223−30 SunOS 5.10_x86: Emulex−Sun LightPulse fibre channel adapter driver v2.31o (only required for Emulex HBAs running Leadville)
125165−12 SunOS 5.10_x86: Qlogic ISP fibre channel device driver v2.29 (only required for Qlogic HBAs running Leadville)
139580−02 SunOS 5.10_x86: zfs Patch
4.  For Sun MPxIO support please review the 'Sun StorEdge Traffic Manager for CLARiiON Release Notes (P/N 300−002−978)' available via EMC PowerLink.
5.  Supports S10_x86 Update 5 (5/08)
6.  Minimum Supported revision
7.  EMC supports ZFS in Solaris 10_x86 11/06 (update 3) or later. The Snapshot and Clone features of ZFS are supported only through Sun Microsystems.
8.  Supports S10_x86 Update 6 (10/08)
9.  SNIA HBA API Supported.
10.  Driver Version V2.26 (Sun Patch 125165−10)
11.  Driver Version V2.28 (Sun Patch 125165−11)
12.  STMS is Sun's Multipathing Software and not an EMC Software product. Please refer to the required release note "SUN StorEdge Traffic Manager for CLARiiON Release Notes", P/N
300−002−978, which can be found on EMC's Powerlink website in Support −> Document Library −> Host Connectivity for the complete Installation information.
13.  Driver Version V2.29 (Sun Patch 125165−12)
14.  BIOS V2.02 (Flash image 1.69)
15.  Supports S10_x86 Update 2 (06/06)
16.  Supports S10_x86 Update 4 (08/07)
17.  Supports S10_x86 Update 3 (11/06)
CLARiiON AX150
03/04/2009