Elation Professional 575E User Manual

Page of 54
 
 
 
Design Spot 575E™ 
©Elation Professional®                                                   40                                             
Design Spot 575E™ 
 
 
Channel 23 - Speed pan/tilt movement: 
0-225 
Max to min speed 
226-235 
Blackout by movement 
236-245 
Blackout by all wheel changing 
246-255 No 
function 
 
 
Channel 24 - Lamp on/off, reset, internal programs: 
0-19 
Color change normal   
20-39 
Color change to any position   
40-59 Lamp 
on 
60-79 
Lamp switch off 
80-84 
All motor reset 
85-87 Scan 
motor 
reset 
88-90 
Colors motor reset 
91-93 
Gobo motor reset 
94-96 
Shutter & Dimmer motor reset 
97-99 Other 
motor 
reset 
100-119 
Internal program 1 (secne1~8 of EPROM) 
120-139 
Internal program 2 (secne9~16 of EPROM) 
140-159 
Internal program 3 (secne17~24 of EPROM) 
160-179 
Internal program 4 (secne25~32 of EPROM) 
180-199 
Internal program 5 (secne33~40 of EPROM) 
200-219 
Internal program 6 (secne41~48 of EPROM) 
220-239 
Internal program 7 (secne49~56 of EPROM) 
240-255 
Music Control (scene of Program 1)