Efficient Networks Siemens Sinamics S120 User Manual

Page of 560
Basic functions 
 
6.15 Terminal Module 41 (TM41) 
 
Drive Functions 
212
 
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4 
6.14.2.4  Integration 
The "position tracking/measuring gearbox" function is integrated in the system as follows. 
Function diagrams (see SINAMICS S List Manual) 
●  4704 Position and temperature sensing, encoders 1 ... 3 
Overview of key parameters (see SINAMICS S List Manual) 
●  p0402 Gearbox type selection 
●  p0411 Measuring gearbox configuration 
●  p0412 Measuring gearbox absolute encoder rotary revolutions virtual 
●  p0413 Measuring gearbox position tracking, tolerance window 
●  p0421 Absolute encoder rotary multiturn resolution 
●  p0432 gear factor encoder revolutions 
●  p0433 gear factor motor/load revolutions 
●  r0477 CO: Measuring gearbox, position difference 
●  r0485 CO: Measuring gearbox, raw encoder value, incremental 
●  r0486 CO: Measuring gearbox, raw encoder value, absolute 
6.15 
Terminal Module 41 (TM41) 
Features 
●  General 
–  Pulse encoder emulation, TTL signals (RS422) 
–  Max. encoder output frequency 256 kHz (e.g. 1500 RPM at 8192 pulses) 
–  1 analog input 
–  4 digital inputs 
–  4 bidirectional digital inputs/outputs 
–  Automatic adjustment of the sampling time for encoder emulation 4099[3] 
●  Pulse encoder emulation by presetting of a speed value (p4400 = 0) 
–  PROFIdrive telegram 3 
–  Own control word (r0898) 
–  Own status word (r0899) 
–  Sequence control (refer to function diagram 9682) 
–  Settable pulse number (p0408) 
–  Enable zero marks (p4401.0)